The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN - MISSING. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
PARAPET | NORTH AND SOUTH PARAPET WALLS - MORTAR AND BRICK SECTIONS - LOOSE AND FALLING. SPALLING BRICKS WITH WASHED OUT MORTAR. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR WINDOWS AT 1ST AND 2ND - METAL TRIM - MISSING. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
RAT PROOF OPENINGS | NORTH ALONG BUILDING AT GRADE - RAT HOLES. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
CHIMNEY HEIGHT | SOUTH METAL CHIMNEY HEIGHT BELOW ROOF LINE. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE - COPING TILES - BROKEN , LOOSE , AND MISSING SECTIONS. WEST EAVES - BROKEN AND ROTTED WITH PEELING PAINT. GUTTER AT WEST - RUSTED WITH HOLES AND LEAKING. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | REAR PORCH AT LANDING BETWEEN 1ST AND 2ND LEVELS - ELECTRIC SERVICE CONDUCTOR WITHIN REACH - ELECTROCUTION HAZARD - DANGEROUS AND HAZARDOUS. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 3 STORY OPEN WOOD PORCH - COLUMNS ERECTED ON CONCRETE SLABS AND CONCRETE BASES - FOUNDATION STATUS UNKNOWN. BEAMS ONLY NAILED TO COLUMNS. LEDGER BEAMS ONLY NAILED TO BUILDING. STRINGERS ONLY NAILED TO COLUMNS AND HEADER JOISTS. TREADS SPLIT AND ROTTED. DECKING LOOSE AND ROTTED. PORCH SWAYS EXCESSIVELY. SINGLE 2 X 8 HEADER FOR STAIRS. GUARDRAILS SPAN UP TO 7' - MISSING MID - SPAN COLUMNS OR POSTS. LOOSE HANDRAILS AND GUARDRAILS WITH MISSING PICKETS. PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR BASEMENT STAIRWAY - GRADE TO BASEMENT - GUARDRAILS - MISSING. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR ROOF STRUCTURE | REAR PORCH ROOF - ROTTED WITH BROKEN AND MISSING WOOD SHEATHING. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXTERIOR APARTMENT DOORS - AT PORCH - WITH METAL GATE AND PADLOCK - HAMPERING EGRESS. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD SMOKE AND CO2 DETECTOR 2ND FLOOR | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPAIR DEFECTIVE LIGHTS IN WASH ROOM 2ND FLOOR | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | REPAIR DEFECTIVE OUTLET IN 2ND FLOOR BEDROOM | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPAIR DEFECTIVE CEILING FAN REAR BEDROOM 2ND FLOOR | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
CONNECT DOWNSPOUT TO SEWER | REAR AT GRADE - DOWNSPOUT NOT CONNECTED TO SEWER. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
REPAIR FENCE | NORTH METAL FENCE - TOP RAIL - BROKEN AND BENT. | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
OPEN TYPE VIOLATION | STOP ALL WORK UNTIL BLDG PLANS AND BLDG PERMIT HAS BEEN OBTAINED SEC. 13-12-080; 13-32-035 | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REPLACED 3 STORY ENCLOSED PORCH SYSTEM, IN REAR OF BLDG | 7812 S LAFLIN ST | COMPLAINT | FAILED | View |