Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
FILE BLDG REGISTRATION | REGISTER BUILDING FOR 2006 | 2817 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BASEMENT MECHANICAL ROOM - SMOKE DETECTOR - OUT OF SERVICE. | 2817 W MONROE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTHEAST CORNER FROM GRADE TO ROOF - WASHED OUT MORTAR INBETWEEN COMMON BRICK AND STONE FACADE. | 2817 W MONROE ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING NO RESPONSE,UNVERIFIED COMPLAINT OF CEILING LEAKING IN UNIT 3.UNVERIFIED DETECTORS AND CONDITIONS. | 2817 W MONROE ST | COMPLAINT | FAILED | View |
SUBMIT FOR APPROVAL PLANS | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
WATCHMAN | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 2817 W MONROE ST | COMPLAINT | CLOSED | View | |
POST OWNER/MANAGERS NAME/# | RELOCATE MANAGEMENT SIGN FROM EAST SIDE OF BUILDING TO NORTHSIDE OF BUILDING WHERE IT IS CONSPICUOUS | 2817 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | TREADS, GRADE-BASEMENT(NORTH), HAVE UNDERGONE DEGRADATION CAUSED BY EXCESSS SALT/WATER APPLIED TO MELT ICE;MISSING AND IMPROPER PICKETS, GRADE TO BASEMENT(SOUTH) | 2817 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | AT BASEMENT-HOLES IN CEILING IN DWELLING UNIT | 2817 W MONROE ST | COMPLAINT | FAILED | View |
DWELLING CLEAN AND SANITARY | AT BASEMENT/2ND FLOOR-DIRTY AND UNSANITARY, ROACHES, UNCOVERED GARBAGE | 2817 W MONROE ST | COMPLAINT | FAILED | View |
PROVIDE | INADEQUATE SEPARATION BETWEEN BOILER, HOT WATER TANKS, AND BASEMENT DWELLING. BOILER AREA IS NOT ENCLOSED, 15-8-220 | 2817 W MONROE ST | COMPLAINT | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | BOILER AREA IS MISSING A "B" DOOR W/PROPER ASSEMBLY AND NO SELF-CLOSER | 2817 W MONROE ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | PLANS W/ PERMIT NEEDED FOR BOILER ROOM "B" DOOR | 2817 W MONROE ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | ENCLOSED PORCH SOUTH WITH ROTTED COLUMN MISSING SECTIONS OF HANDRAIL | 2817 W MONROE ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | DEBRIS ON LANDINGS (SOUTH) | 2817 W MONROE ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | BASEMENT UNIT - SMOKE DETECTOR - MISSING. | 2817 W MONROE ST | PERIODIC | FAILED | View |
CARB MONOX DETECT IN RESID | BASEMENT APARTMENT - CARBON MONOXIDE DETECTOR - MISSING. | 2817 W MONROE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - STONE FACADE - WASHED OUT MORTAR IN VARIOUS LOCATIONS ALSO VERTICAL WASHED OUT MORTAR BETWEEN BRICK AND STONE FACADE. | 2817 W MONROE ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | GAINED ENTRY TO FRONT HALLWAY AND BASEMENT UNIT BUT NOT TO ALL OTHER UNITS TO VERIFY DETECTORS AND CONDITIONS.UNVERIFIED COMPLAINT OF CHIPPING PAINT IN 3RD FLOOR APARTMENT. | 2817 W MONROE ST | PERIODIC | FAILED | View |
MAINTAIN WINDOW | REAR ELEVATION 1ST FLOOR - MISSING FRAME CAPPING | 2817 W MONROE ST | PERIODIC | FAILED | View |
PARAPET & COPING | EAST ELEVATION - LOOSE MORTAR AT PARAPET WITH MISSING COPING AND OPEN JOINTS | 2817 W MONROE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION - SPALLED BOTTOM TREADS/RISER | 2817 W MONROE ST | PERIODIC | FAILED | View |
CHIMNEY CAPPING | CHIMNEY - MISSING CAP | 2817 W MONROE ST | PERIODIC | FAILED | View |
STOP/REMOVE NUISANCE | NORTHWEST ELEVATION - GARABE , RAT HARBORAGE | 2817 W MONROE ST | PERIODIC | FAILED | View |
ARRANGE FOR REINSPECTION REGAR | INTERIOR OF BUILDING , NO RESPONSE . UNABLE TO VERIFY SMOKE OR CARBON MONOXIDE ALARMS. | 2817 W MONROE ST | PERIODIC | FAILED | View |
REPAIR EXTERIOR DOOR FRAME | REAR 1ST FLOOR ENTRANCE DOOR - ROTTED FRAME | 2817 W MONROE ST | PERIODIC | FAILED | View |
REPAIR SCREENS | ALL ELEVATIONS - MISSING OR TORN SCREENS | 2817 W MONROE ST | PERIODIC | FAILED | View |
POST OWNER NAME OF VACNT BLDG | VIOLATION CLOSED PER PCR 1180 | 2817 W MONROE ST | COMPLAINT | CLOSED | View |