Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-22 @ 9:56 PM
PIN: 16012130370000
Property Address: 1422 N CAMPBELL AVE
City - Zip: CHICAGO - 60622
2023 Property Class: 211
2023 Township: 77 - West Chicago
2023 Neighborhood: 77030
2023 Tax District: 77162
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 10 Violations
Violation Inspector Comments Address Category Status View
FILE BLDG REGISTRATION BLDG. - NOT REGISTERED FROM 1990 THRU 2013 1422 N CAMPBELL AVE COMPLAINT FAILED View
REPLACE D&H PORCH 2-STORY / REAR PORCH: 4X4 AND 6X6 COLUMNS ERECTED ON CONCRETE BLOCKS WITHOUT BASES - FOUNDATION STATUS UNKNOWN. COLUMNS ARE OVER-NOTCHED WITH 2X8 BEAMS ON BOTH SIDES. 6X6 BEAM PULLING AWAY FROM COLUMN FIRE-CUTS THRU-OUT. COLUMN SPLICE CONNECTIONS ARE IN CLOSE PROXIMITY TO BEAM-COLUMN CONNECTION POINTS, WITH SPLICE OVER-LAP OF ONLY 8 INCHES AND TWO BOLTS. COLUMNS ARE OUT OF PLUMB AT COLUMN CONNECTIONS. STRINGERS ARE SPLIT AND OVER-CUT. OPEN BEAM POCKETS ON MASONRY WALL THRU-OUT. LANDING JOISTS ARE ONLY TOE-NAILED TO RIM BEAMS. 4X4 RAILING NEWEL POST LOOSE, PULLING AND ONLY ATTACHED TO STRINGERS WITH NAILS. GUARDRAIL HEIGHTS ARE ONLY 32 INCHES, LOOSE, PULLING AND SPAN 6 FEET, WITH TOP RAIL NAILS LOOSE AND PROTRUDING OUT. TREADS ARE ONLY 9 INCHES WIDE NAILS PROTRUDING OUT. 2 TO 3 INCHES GAP BETWEEN LEDGER BOARDS AND WALL. ENTIRE STRUCTURE IS WEAK, UNSTABLE AND SWAYING. PLANS AND PERMIT REQUIRED TO REPLACE REAR PORCH. 1422 N CAMPBELL AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING APT. 2R - KITCHEN AND BATHROOM CEILINGS - WATER DAMAGE. REAR (CENTER) INTERIOR STAIRWELL - HOLES ON WALL. 1422 N CAMPBELL AVE COMPLAINT FAILED View
REPAIR GUTTER REAR GUTTER - BROKEN AND TWISTED. 1422 N CAMPBELL AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS, INCLUDING IR, 1F, 2F AND BASEMENT: NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. 1422 N CAMPBELL AVE COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM REAR INTERIOR (CENTER) STAIRWAY - RAILING SECTIONS ARE OF "LADDER" TYPE, WITH HORIZONTAL TIES SPACED 11 INCHES APART. 1422 N CAMPBELL AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE ALL APARTMENT DOORS - MISSING VIEWING DEVICE. 1422 N CAMPBELL AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BLDG. - OWNER'S I.D. SIGN - MISSING 1422 N CAMPBELL AVE COMPLAINT FAILED View
STOP LEAKING WATER APT. 2R - KITCHEN AND BATHROOM - WATER LEAKING FROM CEILING. 1422 N CAMPBELL AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM EAST ELEVATION: GRADE TO 1 / FRONT PORCH: 4X4 COLUMNS ERECTED ON BROKEN RETAINING WALLS AND SERVICE WALK WITHOUT BASES - FOUNDATION STATUS UNKNOWN. UNDERSIZED 2X6 DECK JOISTS SPAN 6 FEET, SPACED 20 INCHES APART AND ONLY TOE-NAILED TO HEADERS. TREADS BUCKLED AND RISERS BROKEN. GUARDRAIL SECTIONS ARE ONLY 36 INCHES HIGH, MISSING TOP RAILS AND ONLY TOE-NAILED TO WALL. PERMIT ONLY (NO PLANS) REQUIRED TO REPLACE FRONT PORCH. 1422 N CAMPBELL AVE COMPLAINT FAILED View