REPAIR PORCH SYSTEM | WEST ELEVATION,GRADE TO 1ST FLOOR,FRONT EXTERIOR PORCH,4 BY 4 COLUMNS SET ON CONCRETE BLOCKS,LEDGER BOARD IS FACE NAILED ONLY,JOISTS ARE FACE NAILED,RAILS ARE 36 INCHES HIGH WITH 6 1/2 INCH SPACING ON PICKETS WITH PICKETS ON THE OUT SIDE OF RAILS.PERMIT REQUIRED. EAST ELEVATION,REAR EXTERIOR PORCH GRADE TO ATTIC,COLUMNS ARE SET ON SIDE WALK,1ST FLOOR LEDGER FACE NAILED ONLY,JOISTS ARE 2 BY 6 AND SPAN 11 FOOT 10 INCHES.BEAMS HAVE LIGHT GAGE METAL AT COLUMN CONNECTIONS,COLUMNS ARE 4 BY 6 WITH HALF-LAP JOINTS FACE NAILED AND SCABB LUMBER.RAILS ARE 38 INCHES HIGH LOOSE AND PULLING,RAILS ARE TOE NAILED TO SUPPORTS.STAIR STRINGERSARE FACE NAILED AT TOP CONNECTION,STAIRS STRINGER TO ATTIC IS FACE NAILED TO GUARD RAIL SUPPORT POST.DECKING BOARDS ARE SPLITTING.PLANS AND PERMIT REQUIRED FOR REPAIRS OR REPLACEMENT. | 4737 S ADA ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING NO ENTRY TO BASEMENT,1ST FLOOR REAR AND ATTIC TO CHECK OCCUPANCY,DETECTORS. | 4737 S ADA ST | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY,2ND FLOOR,MISSING SMOKE DETECTOR. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT EXTERIOR STAIRS GUARD RAILS ARE 32" IN HEIGHT NAILED TO WALL WITH LOOSE SECTIONS. FLOOR JOISTS ARE TOE NAILED ONLY, 4X4 COLUMNS ARE ERECTED ON GROUND. MUCH ROTTED WOOD ON STAIRS. | 4737 S ADA ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTORS MISSING AT FRONT INTERIOR STAIRS - 2ND FLOOR - 1ST FLOOR FRONT AND REAR - BASEMENT UNIT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTORS MISSING ON 2ND FLOOR - BASEMENT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | 2ND FLOOR FRONT ENTRY DOOR SWINGS OUTWARD - REHANG TO SWING INSIDE. BASEMENT FRONT DOOR IN EXISTING DWELLING UNIT IS ONLY 4'10" IN HEIGHT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
INSTALL DEAD BOLT LOCK | BASEMENT REAR ENTRY DOOR MISSING DEAD BOLT LOCK. | 4737 S ADA ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 4737 S ADA ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT - 1ST FLOOR FRONT AND REAR HAVE ONLY ONE MEANS OF EGGRESS, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4737 S ADA ST | COMPLAINT | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | 1ST FLOOR FRONT AND REAR APARTMENTS HAVE ONLY ONE MEANS OF EXIT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | BUILDING REAR 2 STORY WOOD PORCH WITH ATTIC ACCESS - COLUMNS ERECTED ON CONCRETE BLOCK WITH FOUNDATION STATUS UNKNOWN. GUARD RAILS ARE 36" IN HEIGHT WITH LOOSE SECTIONS AT 1ST FLOOR AND STAIRS TO GRADE. STAIR STRINGER - 1ST TO 2ND FLOOR BROKEN AT 1ST FLOOR, STRINGERS ATTACHED WITH NAILS ONLY. FLOOR JOIST ARE 2X6X10' ARE INSTALLED 24" ON CENTER, WOOD BLOCKS ARE BEING USED TO SUPPORT THE FLOOR JOIST AT BEAMS. 4X6 AND 6X6 COLUMNS WITH MUCH ROTTING AT BEAM CONECTIONS SUPPORTED WITH SISTERING COLUMNS. DANGEROUS POSTED PLANS AND PERMIT REQUIRED FOR REPLACEMENT | 4737 S ADA ST | COMPLAINT | FAILED | View |
FLUE PIPE CLEARANCE 6"X | BASEMENT DWELLING - SPACE HEATER FLUE PIPES ARE HORIZONTAL WITH A DOWNWARD VENTING, RE-ROUT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
INTERIOR FINISH FIRERESISTANCE | BASEMENT 2 WATER HEATERS INSTALLED IN CLOSETS WITH EPON WALL AND CEILING STUDS - SOME WALLS COVERED WITH WOOD PANELLING. | 4737 S ADA ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES INSTALLED IN THE BASEMENT WITHOUT A PERMIT. | 4737 S ADA ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT - 1ST FLOOR FRONT AND REAR HAVE ONLY ONE MEANS OF EGGRESS, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. | 4737 S ADA ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | BUILDING REAR 2 STORY WOOD PORCH WITH ATTIC ACCESS - COLUMNS ERECTED ON CONCRETE BLOCK WITH FOUNDATION STATUS UNKNOWN. GUARD RAILS ARE 36" IN HEIGHT WITH LOOSE SECTIONS AT 1ST FLOOR AND STAIRS TO GRADE. STAIR STRINGER - 1ST TO 2ND FLOOR BROKEN AT 1ST FLOOR, STRINGERS ATTACHED WITH NAILS ONLY. FLOOR JOIST ARE 2X6X10' ARE INSTALLED 24" ON CENTER, WOOD BLOCKS ARE BEING USED TO SUPPORT THE FLOOR JOIST AT BEAMS. 4X6 AND 6X6 COLUMNS WITH MUCH ROTTING AT BEAM CONECTIONS SUPPORTED WITH SISTERING COLUMNS. DANGEROUS POSTED PLANS AND PERMIT REQUIRED FOR REPLACEMENT | 4737 S ADA ST | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | REAR ELECTRICAL SERVICE CONDUCTOR JUNCTION BOX - EXPOSED WIRES - COVER MISSING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR PORCH - ON DECKS - LATTICE , TOILET , DOOR, BOXES , PERSONAL ITEMS , JUNK AND DEBRIS - HAMPERING EGRESS. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EAVES | REAR GABLE EAVES - FASCIA - METAL CAPPING - BROKEN AND MISSING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | REAR AT 1ST - WINDOW - BROKEN PANE. | 4737 S ADA ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | BUILDING INTERIOR - NO RESPONSE - UNVERIFIED DETECTORS AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. | 4737 S ADA ST | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING NOT REGISTERED FROM 2005 THROUGH 2015. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EAVES | REAR ELEVATION - EAVES /FASCIA - SECTIONS MISSING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR | FRONT ELEVATION - BASEMENT DOOR /DOOR - WORN AND CHIPPING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE OVER HEAD DOOR IS LOOSE AND HANGING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR SCREENS | WINDOW SCREENS - MANY BROKEN AT VARIOUS LOCATIONS. | 4737 S ADA ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | SOUTH ELEVATION - BASEMENT WINDOW /PANE - MISSING; BOARDED WITH PLYWOOD. | 4737 S ADA ST | COMPLAINT | CLOSED | View |
REPAIR EAVES | REAR ELEVATION - EAVES /FASCIA - SECTIONS MISSING. | 4737 S ADA ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION - WOOD ENTRY STAIR /TREADS - CRACKING AND ROTTING. /RAILS - SECTIONS BROKEN. | 4737 S ADA ST | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION /SIDEWALK - CRACKING AND HOLDING WATER. | 4737 S ADA ST | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | SOUTH ELEVATION - BASEMENT WINDOW /PANE - MISSING; BOARDED WITH PLYWOOD. | 4737 S ADA ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | REAR ELEVATION - ON PORCH /GRILL AND FURNITURE - SITTING ON DECKING. | 4737 S ADA ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | FRONT ELEVATION - WOOD ENTRY STAIR /TREADS - CRACKING AND ROTTING. /RAILS - SECTIONS BROKEN. | 4737 S ADA ST | COMPLAINT | CLOSED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH ELEVATION /SIDEWALK - CRACKING AND HOLDING WATER. | 4737 S ADA ST | COMPLAINT | CLOSED | View |
STOP/REMOVE NUISANCE | REAR ELEVATION - ON PORCH /GRILL AND FURNITURE - SITTING ON DECKING. | 4737 S ADA ST | COMPLAINT | CLOSED | View |
REPAIR EXTERIOR DOOR | FRONT ELEVATION - BASEMENT DOOR /DOOR - WORN AND CHIPPING. | 4737 S ADA ST | COMPLAINT | CLOSED | View |