The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
NO KEY TO USE EXIT DOOR | GATES ALL HAVE CHAINS AND PADLOCKS.JCH | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | STEEL GIRDER AT FRONT OF BUILDING HAS RUST AND IS PUSHING OUT BRICKS AND MORTAR OVER PUBLIC WAY. CEMENT SKIN COAT AT SOUTH AND WEST ELEVATION IS SEPARATING FROM BUILDING AND ERRODING.OBTAIN PERMIT.JCH | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
GRADE AND DRAIN LOT | HAS LOOSE AND DETERIORATING ASPHALT.JCH | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
NO BARBED WIRE ON FENCE < 8FT | HAS BARBED WIRE AT ALLEY.JCH | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | OWNER'S ID IS NOT POSTED.JCH | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | 6452 S./ FRONT ELEVATION/ EXTERIOR WALL -SHIFTED DANGEROUSLY AWAY FROM BUILDING. SEVERELY BULGING NEAR NORTH END AT MID RANGE; FRACTURED MASONRY AND SEPARATING FROM NORTH ELEVATION BRICKS WITH MISSING BRICKS AND WASHED OUT MORTAR.NORTH ELEVATION/ EXTERIOR WALL - LARGE FRACTURES AND SEPARATING FROM FRONT EXTERIOR WALL WITH LARGE VOIDS BETWEEN BRICKS.DANGEROUS AND HAZARDOUS CONDITIONS.PLANS AND PERMIT REQUIRED FOR MASONRY REPAIRS. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ELEVATION/ STEEL LINTEL/GIRDER - RUSTED AND SHIFTED.PLANS AND PERMIT REQUIRED TO REPLACE. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
PROTECT SIDEWALK DURING CONST | FRONT OF BUILDING - INSTALL PROTECTIVE CANOPY OVER PUBLIC SIDEWALK.PERMIT ISSUED BY DEPARTMENT OF TRANSPORTATION REQIRED FOR THIS INSTALLATION. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | FRONT ELEVATION/ WINDOW SILLS - WASHED OUT MORTAR. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR ELEVATION/ GRADE TO BASEMENT EXTERIOR STAIRWAY - MISSING GUARD RAIL AT GRADE. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR ELEVBATION/ GRADE TO BASEMENT EXTERIOR STAIRWAY - MISSING HAND RAIL. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR ELEVATION/ EXTERIOR PLATFORM OVER GRADE TO BASEMENT WELL - SINGLE 2X6 BEAMS - SEVERELY ROTTED AND SHIFTED. 2X6 DECK JOISTS - ROTTED, ONLY NAILED TO RIM BOARD AND SHIFTED OFF BEAM LEAVING ONLY 1/2 INCH OF WOOD REMAINING ON BEAM. RAILINGS - LOOSE AND PULLING; ROTTED.DANGEROUS AND HAZARDOUS CONDITIONS.(FALLING DOWN HAZARD, BASEMENT WELL APPROXIMATELY A 10 FOOT DROP).PLANS AND PERMIT REQUIRED TO REPLACE PLATFORM. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2-STORY WOOD PORCH/ BEAMS - ONLY NAILED TO COLUMNS. UNDERSIZED 2X8 DECK JOISTS SPAN 9 TO 10 FEET AND ARE ONLY NAILED TO HEADER BEAM. STRINGERS - UPPER ENDS INADEQUATELY SUPPORTED WITH NAILS ONLY. 2X12 HEADER IS ONLY NAILED TO COLUMNS. NORTH BEAM HAS AN OPEN WALL POCKET THAT IS MISSING MORTAR. ALL RAILINGS - LOOSE AND PULLING. 2ND FLOOR DECK - ELECTRICAL SERVICE IS WITHIN REACH.PLANS AND PERMIT REQUIRED FOR REAR PORCH REPAIRS. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
OBTAIN OR POST PERMIT | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
MAINTAN BLDG IN SAFE CONDITION | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
REPAIR/WRECK DANGER RESID PREM | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
WATCHMAN | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
VACANT BUILDING - REGISTER | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
POST OWNER INFO ON ABDN BLDG | 6452 S ASHLAND AVE | COMPLAINT | CLOSED | View | |
ARRANGE FOR INSPECTION | INSPECTION | 6452 S ASHLAND AVE | PERIODIC | FAILED | View |
ACCESS TO ROOF | INSPECTION | 6452 S ASHLAND AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO INSPECT COMPLAINT SR901971367. GAS CONNECTION. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |
REPLCE WINDOW PANES, PLEXGLAS | SOUTH ELEVATION/ 2ND FLOOR WINDOW - BROKEN PANE. | 6452 S ASHLAND AVE | COMPLAINT | FAILED | View |