Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR WALL | WEST ELEVATION ERODING MORTAR AND FRACTURES. NORTH ELEVATION AND EAST AND WEST ELEVATIONS AT NORTH END- FRACTURES. OPEN MORTAR JOINTS. NORTH ELEVATION OVER ENTRY MISSING BRICK. STEP FRACTURES NORTH ELEVATION AT ATTIC WINDOW. REAR ENCLOSURE WITH TORN AND DAMAGED SIDING. | 3409 W BELMONT AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | FRONT ENTRY LINTEL RUSTED AND SAGGING. | 3409 W BELMONT AVE | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR FENCE, LOOSE, LEANING, UNSUPORTED. NO PERMIT FOR FENCE ON FILE, OBTAIN PERMIT. | 3409 W BELMONT AVE | COMPLAINT | FAILED | View |
MAINTAIN WINDOW | REAR ENCLOSURE WINDOWS ROTTING SILLS, SASHES AND FRAMES. | 3409 W BELMONT AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | ROOM TEMPERATURE 64 DEGREES LIVING ROOM FRONT BEDROOM 64 DEGREES REAR BEDROOM 63 DEGREES HEATING SYSTEM IS OFF AT TIME OF INSPECTION NO HEAT PROVIDED | 3409 W BELMONT AVE | COMPLAINT | CLOSED | View |
SAFE WORKING CONDITIONS | FUNACE OUT OF SERVICE AT TIME OF INSPECTION | 3409 W BELMONT AVE | COMPLAINT | CLOSED | View |
REPAIR DOOR, INT. | 2ND FLOOR APT ENTRANCE DOOR BROKEN. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT OF BUILDING / 2ND FLOOR WINDOW AND REAR ENCLOSED PORCH WINDOW BETWEEN 2ND AND 3RD FLOORS-MISSING PANES. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | 2 ND FLOOR APT MISSING OUTLET AND SWITCH COVERS | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
PROV HOT WTR TO ALL FIXTURES | 2ND FLOOR KITCHEN SINK HOT WATER NOT PROVIDED. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
PROVIDE COLD WATER TO FICTURES | 2ND FLOOR KITCHEN SINK COLD WATER NOT PROVIDED. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | 2ND FLOOR APT MISSING SMOKE DETECTORS. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 2ND FLOOR APT MISSING CARBON MONOXIDE DETECTOR. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | FURNACE AND HOT WATER HEATER INSTALLED ON 2ND FLOOR DECK OF REAR ENCLOSED PORCH WITHOUT A PERMIT.PLANS AND PERMITS REQUIRED FOR SUCH INSTALLATION,SUBJECT TO FIELD INSPECTION AND APPROVAL BY PLUMBING AND VENTILATION BUREAUS. 1ST FLOOR NON- RESIDENTIAL UNIT RECENTLY REMODELED AND BUILT OUT WITHOUT A PERMIT.PLANS AND PERMITS REQUIRED FOR SUCH INSTALLATION,SUBJECT TO FIELD INSPECTION BY ALL RELATED TRADES. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | EAST AND WEST ELEVATIONS/EXTERIOR WALLS MISSING MORTAR AND SPALLING BRICKS. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
MOTOR DISCONNECT | 2ND FLOOR DISHWASHER | 3409 W BELMONT AVE | PERMIT | PASSED | View |
ARRANGE COMPLETED PERMIT INSP. | 3409 W BELMONT AVE | PERMIT | PASSED | View | |
LAUNDRY BRANCH CIRCUIT | SEPERATE LAUNDRY GFCI CIRCUIT FROM LIGHT | 3409 W BELMONT AVE | PERMIT | PASSED | View |
PLANS & LOAD CALCULATION | PLAN DOES NOT MATCH EXISTING SERVICE | 3409 W BELMONT AVE | PERMIT | PASSED | View |
SIZE EQUIPMENT GROUND COND | INSTALL PROPER GROUND | 3409 W BELMONT AVE | PERMIT | PASSED | View |
REQUIRED OUTLETS AND SPACING | INSTALL REQUIRED COUNTERTOP OUTLET SPACING 2ND FLOOR KITCHEN | 3409 W BELMONT AVE | PERMIT | PASSED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY INTERIOR. | 3409 W BELMONT AVE | COMPLAINT | FAILED | View |
DRYER EXHAUST NUISANCE | 2ND FLOOR APT DRYER EXHAUST VENT DISCONNECTED. | 3409 W BELMONT AVE | COMPLAINT | PASSED | View |
UNAPPROVED HEATING DEVICE | USING COOKING STOVE AS HEATING DEVICE | 3409 W BELMONT AVE | COMPLAINT | CLOSED | View |
BATHROOM BRANCH CIRCUIT | SEPERATE BATH GFCI CIRCUIT FROM LIGHTING | 3409 W BELMONT AVE | PERMIT | PASSED | View |
FEEDER AMPS / COMPUTED LOAD | 2ND FLOOR 100A PANEL | 3409 W BELMONT AVE | PERMIT | PASSED | View |