Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | FRONT CONCRETE STAIRS - SCRAPE AND PAINT RUSTED HAND AND GUARDRAILS. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR 2ND STORY ADDITION TO ATTIC AT REAR TWO THIRDS OF BUILDING. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR FENCE | SCRAPE AND PAINT RUSTED SECTIONS OF STEEL PICKET FENCE EAST. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
SCREEN OUTER DOORS, WINDOWS | MISSING WINDOW SCREENS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE STEEL PICKET FENCE IN EXCESS OF 5 FT. IN HEIGHT WEST ELEVATION REAR YARD "NO PERMIT". | 4520 S WOOD ST | COMPLAINT | FAILED | View |
PROVIDE GUTTER & DOWNSPOUT | MISSING SECTION OF DOWNSPOUT SOUTHWEST CORNER. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | MISSING SECTION OF SIDING WEST WALL 1ST FLOOR BETWEEN WINDOWS. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE EXTERIOR FRONT LIGHT FIXTURE. | 4520 S WOOD ST | COMPLAINT | FAILED | View |
DEFECTIVE METER EQUIPMENT | REPLACE THE METER BOX THAT IS OPEN WITH EXPOSED LIVE PARTS, DANGEROUS AND HAZARDOUS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
DEFECTIVE DISTRIBUTION | PROVIDE PROPER COVER FOR ELECTRICAL PANEL WITH EXPOSED LIVE PARTS, DANGEROUS AND HAZARDOUS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
ADD RECEPTACLES | ADD RECEPTACLES TO EASE EXTENSION CORD USE THROUGHOUT BASEMENT AREAS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
CONTINUITY OF RACEWAY | PROVIDE GROUND CONTINUITY FOR 1/2 INCH CONDUIT ABOVE REAR PORCH ENTRANCE DOOR AREA, DANGEROUS AND HAZARDOUS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
ARMORED CABLE | REPLACE DEFECTIVE AND EXCESSIVE USE OF ARMOURED CABLE THROUGHOUT REAR PORCH AND BASEMENT AREAS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
PROVIDE WEATHER PROOF BOXES, LITES, FITTINGS, AND APPROVED RACEWAYS FOR ALL EXTERIOR LITES AND CONDUIT RUNS 18-27-110.11 | 4520 S WOOD ST | COMPLAINT | FAILED | View | |
OBTAIN ELECTRICAL PERMIT AND CONTRACTOR TO CORRECT VIOLATIONS 13-12-360 | 4520 S WOOD ST | COMPLAINT | FAILED | View | |
REPLACE DEFECTIVE WASTE PIPING | BASEMENT KITCHEN SINK WASTE FROM THE FIRST FLOOR AND THE HORIZONTAL 2 INCH WASTE LINE IS BACKPITCHED | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | THE 2 INCH KITCHEN SINK, HORIZONTAL AND VERTICAL WASTE PIPE ARE TIED IN WITH FERNCO COUPLING, REMOVE AND USE APPROVED CONNECTIONS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE FITTINGS | BASEMENT LAUNDRY TUB WASTE ARM ARE TIED IN WITH A FERNCO COUPLING, REMOVE AND USE APPROVED CONNECTIONS | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPAIR DEFECTIVE DOWNSPOUT | BOTH FRONT DOWNSPOUTS ARE REDUCED FROM 3 INCH VERTICAL TO 2 INCH HORIZONTAL, REPIPE WITH CORRECT SIZE PIPE | 4520 S WOOD ST | COMPLAINT | FAILED | View |
REPLACE DEFECTIVE WASTE PIPING | SECOND FLOOR LAVATORY WASTE MUST BE TIED INTO THE WASTE STACK | 4520 S WOOD ST | COMPLAINT | FAILED | View |
OBTN PERMIT FOR PLUMBING WORK | PULL A PLUMBING PERMIT | 4520 S WOOD ST | COMPLAINT | FAILED | View |
ENGAG LIC & BOND PLMBNG CNTRC | HIRE A LICENSED PLUMBING CONTRACTOR | 4520 S WOOD ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | PROVIDE GFCI PROTECTION FOR ALL KITCHEN COUNTERTOP, BATHROOM, AND LAUNDRY AREAS 18-27-210.8 | 4520 S WOOD ST | COMPLAINT | FAILED | View |