Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-10-23 @ 2:21 PM
PIN: 20033140240000
Property Address: 4520 S INDIANA AVE
City - Zip: CHICAGO - 60653
2023 Property Class: 211
2023 Township: 70 - Hyde Park
2023 Neighborhood: 70010
2023 Tax District: 70118
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING /1ST. FL. AND 3RD. FL. - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS. 4520 S INDIANA AVE COMPLAINT CLOSED View
PARAPET NORTH ELEVATION [AT EAST] /PARAPET WALL - WASHED OUT MORTAR.SOUTH ELEVATION /PARAPET WALL - SPALLING, PARGED, LOOSE WASHED OUT MORTAR.MASONRY PERMIT REQUIRED. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR COPING EAST ELEVATION /COPING - WASHED OUT MORTAR. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR AREAWAY WALL SOUTH ELEVATION /AREAWAY CEILING - EXPOSED WOOD. AREAWAY WALLS - LOOSE PARGED, WASHED OUT MORTAR. 4520 S INDIANA AVE COMPLAINT CLOSED View
MAINTAIN WINDOW EAST ELEVATION /2ND. FL. WINDOW FRAME - ROTTED - EXPOSED WOOD. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR/REPLACE SMOKE DETECTORS FRONT INTERIOR STAIRWAY /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH LOW BATTERY, LOOSE AND HANGING;2ND. FL. APT. /SMOKE DETECTOR ¿ OUT OF SERVICE, WITH LOW BATTERY; 4520 S INDIANA AVE COMPLAINT CLOSED View
PROVIDE DEADLOCK FOR ENTRANCE FRONT ELEVATION /EXTERIOR DOOR - DEADBOLT - MISSING. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR EXTERIOR STAIR FRONT ELEVATION /STONE STEPS - WASHED OUT MORTAR WITH GAPS.RAILINGS /METAL GUARD RAILING SECTIONS ONLY 30 1/2 INCHES HIGH - ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL TIES SPACED UP TO 8 1/2 INCHES APART; METAL STAIR RAIL SECTIONS ARE OF LADDER TYPE DESIGN, WITH ANGLE TIES SPACED UP TO 8 1/2 INCHES APART; 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR PORCH SYSTEM PLANS AND PERMIT REQUIRED.REAR 3 STORY WOOD PORCH.FOUNDATIONS /COLUMNS ERECTED ON TOP OF CONCRETE SLAB, WITH NO BASES; FOUNDATION STATUS UNKNOWN; COLUMNS [SCABBED] /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 16 INCHES, WITH ONLY 4 BOLT USED OF 1/2 INCHES IN DIAMETER; COLUMNS /INADEQUATE HALF-LAP JOINTS WITH OVERLAP OF ONLY 4 INCHES, FASTENED WITH NAILS ONLY. COLUMNS /SPAN UP TO 9 FEET 2 1/2 INCHES APART. ROOF BEAMS /STACKED ON TOP OF COLUMNS, FASTENED WITH NAILS/SCREWS ONLY; STRINGERS /UPPER AND LOWER ENDS OF STRINGERS INADEQUATELY SUPPORTED AT HEADER JOISTS AND COLUMNS, FASTENED WITH NAILS /SCREWS ONLY; STAIRS /RISER HEIGHT NOT UNIFORMED, RANGING FROM 8 INCHES TO 6 1/2 INCHES TO 7 1/2 INCHES. /TREADS - WORN OUT, CRACKED. STRINGERS/STAIR SYSTEM [OPEN RISERS] UNSTABLE ¿ EXCESSIVE PULLING, SWAYING; RAILINGS /GUARD RAILING SECTIONS ONLY 39 INCHES HIGH - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; STAIR RAILING SECTIONS - LOOSE AND PULLING; DEFLECTING UNDER LOAD; WITH TOP AND BOTTOM RAILS PULLING; ALL RAILING SECTIONS FASTENED TO COLUMNS WITH NAILS /SCREWS ONLY; PICKETS MISSING AT LANDING, INSTALLED ON OUTSIDE OF TOP AND BOTTOM RAILS.PLANS AND PERMIT REQUIRED. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR CORNICE EAST ELEVATION /CORNICE - WASHED OUT MORTAR. 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR EXTERIOR DOOR, RESET FRONT ELEVATION /EXTERIOR DOOR ¿ TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM; 4520 S INDIANA AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL EAST ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR.SOUTH ELEVATION /EXTERIOR WALL - SPALLING, PARGED, LOOSE WASHED OUT MORTAR.MASONRY PERMIT REQUIRED. 4520 S INDIANA AVE COMPLAINT CLOSED View
STOP/REMOVE NUISANCE ABANDONED VEHICLES IN REAR 4520 S INDIANA AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND CONDITIONS. 4520 S INDIANA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION /EXTERIOR WALL - WASHED OUT MORTAR.SOUTH ELEVATION /EXTERIOR WALL - SPALLING, PARGED, LOOSE WASHED OUT MORTAR.MASONRY PERMIT REQUIRED. 4520 S INDIANA AVE COMPLAINT FAILED View
REPAIR CORNICE EAST ELEVATION /CORNICE - WASHED OUT MORTAR. 4520 S INDIANA AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET FRONT ELEVATION /EXTERIOR DOOR ¿ TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM; 4520 S INDIANA AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH ELEVATION /2ND. FL. WINDOW - BROKEN PANE. 4520 S INDIANA AVE COMPLAINT CLOSED View