Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING /BASEMENT AND 2ND. FL. - NO RESPONSE. UNABLE TO VERIFY DETECTORS, CONDITIONS. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING /OWNER¿S I.D. SIGN ¿ MISSING; | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | NORTH AND SOUTH ELEVATIONS /EXTERIOR WALLS - WASHED OUT MORTAR.WEST ELEVATION /EXTERIOR WALL - FRACTURED, SHIFTED BRICK, BULGING OUTWARD, WITH WASHED OUT MORTAR. WEST ELEVATION /EXTERIOR WING WALL - WASHED OUT MORTAR.MASONRY PERMIT REQUIRED TO REPAIR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR COPING | WEST ELEVATION /COPING - WAHSED OUT MORTAR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR CORNICE | WEST ELEVATION /CORNICE - WAHSED OUT MORTAR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | NORTH AND WEST ELEVATION /STONE WINDOW SILLS - FRACTURED, SHIFTED, WITH WASHED OUT MORTAR. SOUTH ELEVATION /STONE WINDOW SILLS - WASHED OUT MORTAR.MASONRY PERMIT REQUIRED TO REPLACE/REPAIR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | WEST ELEVATION /STONE LINTEL - FRACTURED, CRACKED, SAGGING.MASONRY PERMIT REQUIRED TO REPLACE. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
CHIMNEY | SOUTH ELEVATION /CHIMNEY - LOOSE, MISSING BRICK, WITH WASHED OUT MORTAR.MASONRY PERMIT REQUIRED TO REPAIR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
CHIMNEY CAPPING | NORTH ELEVATION /CHIMNEY CAPPING - MISSING. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR HARDWARE | FRONT ELEVATION /EXTERIOR DOOR HARDWARE [CLOSER] - MISSING. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR DOOR HARDWARE | FRONT ELEVATION /INTERIOR FOYER DOOR HARDWARE AND CLOSER - MISSING.1ST. FL. APT. /INTERIOR BATHROOM DOOR HARDWARE - BROKEN, WITH PEELING VENEER. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | 1ST. FL. APT. MOST WINDOW FRAMES - ROTTED, FLAKING PAINT, DRAFTY.NORTH ELEVATION /2ND. FL. WINDOW FRAMES - ROTTED. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
PARAPET | NORTH ELEVATION /PARAPET WALL - WASHED OUT MORTAR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
MICE/RODENTS | BUILDING THROUGHOUT ¿ MICE, DROPPINGS OBSERVED IN 1ST. FL. APT. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | FRONT AND REAR YARD GATES - CHAINED AND PAD LOCKED. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
RESET LOOSE FIXTURE | 1ST. FL. APT. /TOILET - LOOSE WITH CRACKED, FRACTURED TANK.1ST. FL. APT. THROUGHOUT /RADIATORS - LOOSE.1ST. FL. APT. /DINING ROOM [BUILD IN CABINETS] DOOR - MISSING, DOOR - OFF HINGES. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR FLOOR | FRONT FOYER /FLOOR TILE - CRACKED - MISSING.1ST. FL. APT. /KITCHEN AND BATHROOM FLOOR - CRACKED, MISSING TILE. 1ST. FL. APT. THROUGHOUT /FLOORS [AT RADIATORS] - HOLES. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR, RESET | 1ST, FL. APT. /FRONT AND REAR ENTRY DOORS - TOO SMALL FOR FRAME, WITH GAPS AT BOTTOM AND SIDES; | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
PROVID SELF CLSING SCREEN DVCE | 1ST. FL. APT. /REAR SCREEN DOOR HARDWARE - BROKEN - [CLOSER] -MISSING. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | FRONT ELEVATION /1ST. FL. WINDOW - BROKEN PANE. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
RELOCATE SMOKE DETECTOR | FRONT INTERIOR STAIRWELL /RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 19 INCHES FROM CEILING ON THE WALL;1ST. FL. APT. /RELOCATE SMOKE DETECTOR INSTALLED TOO LOW 37 INCHES FROM CEILING ON THE WALL; | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | 1ST. FL. APT. /CARBON MONOXIDE DETECTOR - MISSING. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE /NORTH ELEVATION /EXTERIOR WALL - LOOSE SHIFTED BRICK [OVER SERVICE DOOR], WITH WASHED OUT MORTAR; OVERHEAD DOOR [TRIM] /BROKEN, LOOSE, CRACKED, ROTTED.MASONRY PERMIT REQUIRED TO REPAIR. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
REPAIR ROOF | REAR ELEVATION /ROOF AT PORCH. ROOF BEAMS [6X6 LOOK-OUTS] /NOT TIED BACK TO THE WALL INSIDE THE BEAM POCKET, MISSING STRAPS OR ANCHORS; SCABBED TO COLUMNS.ROOF JOISTS /2X8 - ROTTED AT ALL CONNECTIONS.PERMIT REQUIRED TO REPLACE. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
STOP/REMOVE NUISANCE | REAR YARD /CABLE LINES HANGING ON GARAGE ROOF FROM ALLEY POLE. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | SUPPORT FIXTURE LIGHT FIXTURE A ENTRANCE FOYER | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | DEFECTIVE OUTLET INSTALL 3 PRONG GROUNDING RECEPTACLES THRU OUT SUPPORT RECEPTACLE IN BEDROOM | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION OUTSIDE FRONT & BACK ENTRANCES | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
EXPOSED WIRING | EXPOSED WIRING EXPOSED ELECTRICAL WIRING ON 1ST FLOOR BALCONY & IN GARAGE NORTH WALL | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
SECURE SEC | SECURE SE CABLE POORLY SECURED SERVICE ENTRANCE CABLE RUNNING ON OUTSIDE DECK | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | "TEXT" SMOKE DETECTOR TOO LOW IN REAR HALL | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT FOYER /WALL TILE - LOOSE AND HANGING.FRONT INTERIOR STAIRWELL / CEILING - PEELING PAINT.1ST. FL. APT. THROUGHOUT /WALLS AND CEILINGS - CRACKED, PEELING PAINT, WITH WATER DAMAGE. NOTE: FLOOR UNDER KITCHEN SINK AND WALL/FLOOR BEHIND STOVE/RANGE. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW SASH | 1ST. FL. APT. MOST WINDOW SASHES - ROTTED, FLAKING PAINT, DRAFTY. DO NOT OPEN. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | DEFECTIVE FIXTURE BROKEN FIXTURE IN BACK BEDROOM | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
SECURE RACEWAY | UNSUPPORTED CONUIT ON NE CORNER OUTSIDE NO WEATHER PROOF BOX | 7921 S MORGAN ST | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | FRONT ELEVATION /1ST. AND 2ND. FL. ENTRY DOOR - VIEWING DEVICES - MISSING. | 7921 S MORGAN ST | COMPLAINT | PASSED | View |