The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
OBTN PERMIT FOR PLUMBING WORK | PERMIT FOR VIOLATIONS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | MISSING CHIMNEY CAP WEST. LOOSE BRICKS WEST CHIMNEY OVER PARKING LOT. (18-28-801.2) | 5219 W LAKE ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | OPEN MORTAR JOINTS, LOOSE BRICKS WEST WALL, NORTH WALL BOWING TOWARD SIDEWALK. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PARAPET & COPING | SEPARATION FROM PARAPET BOWED OVER NORTH SIDEWALK. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
REPAIR LINTELS | RUSTED LINTELS ABOVE NORTH OVERHEAD DOORS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
RESTORE ROOF LIVE LOADTO ORIG | HANGING FURNACE FROM BOW TRUSS ROOF, 2 LOCATIONS AT INTERIOR. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
SUBMIT STRUCT. ENG. RPT (INT.) | EXTENSIVE REPAIR TO BOW TRUSS ROOF SYSTEM, NO PERMITS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | SOUTH ELEVATION EAST END PADLOCKED MARKED EXIT. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REAR SOUTH ELEVATION CHAIN LINK FENCE IN EXCESS OF 8 FT. IN HEIGHT. BARBED WIRE ON SOUTH FENCE. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
REPAIR / REBUILD SHED | REAR CINDERBLOCK SHED SOUTH WALL COLLAPSING. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | MEZZANINE OFFICE AREA CONSTRUCTED WITHOUT PERMIT. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | PROVIDE RPZ ON SILCOCKS EAST WALL SILCOCK HAS NO PROTECTION. (18-29-608.13.2) | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | NO TRIPLE BASIN IN GARAGE. (18-29-1003.7.2) | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | NO FLOOR DRAIN AT WATER HEATER. (18-29-412.4) WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE HOT WATER TO FIXTURES | NO COLD WATER AT LAVATORY WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | NO HOT WATER AT LAVATORY WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEXIBLE SUPPLIES TO TOILET AND LAVATORY WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PRV DISCHARGE PIPE FROM PRV | REMOVE PVC DISCHARGE PIPE ON PRV VALVE WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
LICENSED BONDED PLMBG CONTRCTR | OBTAIN A LICENSED PLUMBER TO DO PLUMBING WORK. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
CORRODED CONDUIT & EQUIP | REMOVE DEFECTIVE, RUSTED AND ABANDONED ELECTRICAL CONDUIT AND LIGHT FIXTURE AT REAR OF BUILDING - DANGEROUS AND HAZARDOUS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | REMOVE ALL UNAPPROVED EXTENSION CORDS AND INSTALL ADDITIONAL RECEPTACLES TO AVOID USE OF CORDS - DANGEROUS AND HAZARDOUS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | REPLACE DEFECTIVE LIGHT FIXTURES IMPROPERLY INSTALLED. NEED TO INSTALL CHASE NIPPLES TO EFFICIENTLY GROUND ALL ROWS OF LIGHT FIXTURES - DANGEROUS AND HAZARDOUS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ENTIRE PREMISES INCLUDING REAR AREA OF BUILDING. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE PERMIT TO CORRECT VIOLATIONS. (13-12-360) | 5219 W LAKE ST | COMPLAINT | PASSED | View | |
STOP/REMOVE NUISANCE | REAR CINDERBLOCK SHED LOADED WITH JUNK AND DEBRIS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | NO MOP SINK OR LAUNDRY TUB. (18-29-403.1) | 5219 W LAKE ST | COMPLAINT | PASSED | View |
FIRE EXTNGSHR REQ, RESDNTL | FIRE EXTINGUISHERS EXPIRED TAGS. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
REMOVE | REMOVE 4" PVC DOWNSPOUT NORTHWEST ELEVATION AND PROVIDE PROPER MATERIAL. (18-29-1102.1) | 5219 W LAKE ST | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE TRAP | TRAP NOT CONNECTED AT LAVATORY WEST ELEVATION. | 5219 W LAKE ST | COMPLAINT | PASSED | View |
PROVIDE | NO TEMPERING VALVE AT LAVATORY WEST ELEVATION. (18-29-607.1.1) | 5219 W LAKE ST | COMPLAINT | PASSED | View |