The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
PLANS & PERMITS REQ - CONTRCTR | BASEMENT SPACES/ROOMS BUILT WITH NO PLANS OR PERMITS ON FILE - PLANS AND PERMITS REQUIRED FOR EXISTING ROOMS TO REMAIN OR DECONVERSION PERMIT REQUIRED TO RESTORE THE BASEMENT TO ONE LARGE OPEN SPACE/ROOM | 6541 S KEATING AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | SOUTH STAIRWAY SECOND FLOOR CEILING - SMOKE DETECTOR MISSING | 6541 S KEATING AVE | COMPLAINT | FAILED | View |
SERVICE DROP OUT OF REACH | REAR PORCH | 6541 S KEATING AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | FRONT GRADE TO 1ST FLOOR EXTERIOR STAIRWAY/ ALL METAL RAILINGS - RUSTED. | 6541 S KEATING AVE | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | REAR 2-STORY WOOD PORCH/ COLUMNS - RESTING ON CONCRETE, FOUNDATION STATUS UNKNOWN. ALL RIM JOISTS ARE ONLY NAILED TO COLUMNS. UNDERSIZED 2X8 DECK JOISTS SPAN APPROXIMATELY 12 FEET. STRINGERS - UPPER END ARE INADEQUATELY SUPPORTED WITH NAILS ONLY. 2ND FLOOR DECK - LEDGER BOARD IS ONLY NAILED TO BUILDING'S EXTERIOR WALL. 2ND FLOOR UNDERSIZED 2X8DECK JOISTS SPAN 12 FEET AND ARE ONLY NAILED TO RIM JOISTS. ALL RAILINGS - LOOSE, PULLING AND ONLY NAILED TO COLUMNS AND POSTS. 2ND FLOOR GUARDRAILS - ONLY 37 INCHES HIGH. ENTIRE 1ST FLOOR DECK PROJECTS 12 FEET FROM BUILDING. PLAN AMD PERMIT REQUIRED TO REPLACE REAR PORCH. | 6541 S KEATING AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S I.D. SIGN POSTED. | 6541 S KEATING AVE | COMPLAINT | PASSED | View |