Chicago Building Violations Data: 18 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL NORTH ELEVATION & WEST ELEVATION WASHED OUT MORTAR GRADE TO 3RD FLOOR, SOUTH ELEVATION, 652-54 3RD FLOOR FRACTURED MASONARY AND BULGING BRICK. ALSO 648 FRACTURED MASONARY. 652-54 CRACKED LIME STONE AROUND WINDOW 2ND FLOOR PERMIT REQUIRED. 648 E 50TH ST PERIODIC PASSED View
CHIMNEY CHIMNEY - NORTH ELEVATION. WASHED OUT MORTAR. 648 E 50TH ST PERIODIC PASSED View
OBSTRUCTIONS IN EXIT WAY REAR GATE CHAINED AND LOCKED. 648 E 50TH ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION BUILDING - NO ENTRY TO MOST UNITS. 648 E 50TH ST PERIODIC PASSED View
ARRANGE PREMISE INSPECTION BUILDING INTERIOR NO ENTRY, UNVERIFIED DETECTORS. 648 E 50TH ST PERIODIC FAILED View
REPAIR EXTERIOR WALL REAR ELEVATIONS WALLS HAVE WASHED OUT MORTAR & SPALLING BRICK 648 E 50TH ST PERIODIC FAILED View
RAT PROOF OPENINGS 648 E 50 ST UNIT 3 OPENINGS AROUND PIPES, RADIATOR, SINK, ECT, AND BETWEEN WALL AND FLOOR. 648 E 50TH ST COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO BASEMENT AND MOST APARTMENTS 648 E 50TH ST PERIODIC FAILED View
REPAIR PORCH SYSTEM REAR PORCH 648-54 GRADE TO 3RD COLUMNS NOT PROPERLY SPLICED & BOLTED JOIST TOO SMALL FOR SPAN, IMPROPER BEAM TO COLUMN CONNECTION, 3RD FLOOR LOOSE RAILING 4950 REAR PORCH GRADE TO 3RD COLUMNS NOT PROPERLY SPLICED & BOLTED, JOIST ARE TOO SMALL IMPROPER BEAM TO COLUMN CONNECTIONS 3RD FLOOR RAILING IS WEAK. 4956-58 REAR PORCH COLUMNS NOT PROPERLYSPLICED & BOLTED, COLUMNS ARE OVER NOTCHED LEDGER BOARDS FOR DECKS ARE NOT PROPERLY BOLTED. STRINGERS ARE NOT PROPERLY ATTACHED 648 E 50TH ST PERIODIC FAILED View
PLANS & PERMITS REQ - CONTRCTR OBTAIN PLANS & PERMIT FOR REPAIRS TO ALL PORCHES 648 E 50TH ST PERIODIC FAILED View
FILE BLDG REGISTRATION REGISTER BUILDING 648 E 50TH ST PERIODIC FAILED View
REPAIR EXTERIOR WALL REAR ELEVATIONS WALLS HAVE WASHED OUT MORTAR & SPALLING BRICK 648 E 50TH ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION NO ENTRY TO CONDUCT ANNUAL INSPECTION AND TO ANSWER THE 311 COMPLAINT SR19-1518412. 648 E 50TH ST PERIODIC FAILED View
REPAIR FENCE WEST AND NORTH ELVATION/IRON FENCE - 120X6FT PERMIT REQUIRED, 648 E 50TH ST PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING ¿ NO RESPONSE TO CHECK DETECTOR AND CONDITIONS. 648 E 50TH ST PERIODIC FAILED View
OBSTRUCTIONS IN EXIT WAY REAR GATE CHAINED AND LOCKED. 648 E 50TH ST PERIODIC PASSED View
MICE/RODENTS 648 E 50 3RD FL TENANT SHOWED MICE DROPPING. 648 E 50TH ST COMPLAINT FAILED View
REPAIR INTERIOR STAIR SYSTEM 648 E 50 FRONT INTERIOR STAIRWELL LOOSE TREADS 2ND FLOOR DOWN FROM 2ND FLOOR LANDING. 648 E 50TH ST COMPLAINT FAILED View