Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | OWNER'S I.D. SIGN IS NOT POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | REAR YARD/REAR PORCH/BUILDING INTERIOR-NO RESPONSE, UNVERIFIED DETECTORS, OCCUPANCY AND CONDITIONS FOR ANNUAL INSPECTION PURPOSES. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR ENCLOSED PORCH AT (2) - FURNACE ENCLOSURE; FURNACE AND WATER HEATER INSTALLED WITH OUT A PERMIT | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | REAR ENCLOSED PORCH AT (2) HEATING PLANT ENCLOSURE IS MISSING A CEILING. PLANS AND PERMIT REQUIRED FOR THE CONSTRUCTION OF HEATING PLANT ENCLOSURE | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | REAR ENCLOSED PORCH - PROVIDE CLASS - B FIRE DOOR WITH COMPLETE ASSEMBLE FOR HEATING PLANT ENCLOSURE. PLANS AND PERMIT REQUIRED FOR FIRE DOOR INSTALLATION. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR ENCLOSED PORCH AT (2) - FURNACE ENCLOSURE; FURNACE AND WATER HEATER INSTALLED WITH OUT A PERMIT | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | REAR ENCLOSED PORCH AT (2) HEATING PLANT ENCLOSURE IS MISSING A CEILING. PLANS AND PERMIT REQUIRED FOR THE CONSTRUCTION OF HEATING PLANT ENCLOSURE | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | REAR ENCLOSED PORCH - PROVIDE CLASS - B FIRE DOOR WITH COMPLETE ASSEMBLE FOR HEATING PLANT ENCLOSURE. PLANS AND PERMIT REQUIRED FOR FIRE DOOR INSTALLATION. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
OBTAIN PERMIT BEFORE SIGN WORK | SING READ, BLUE CHICAGO FINANCIAL.ELECTRONIC BOARD, APPROXIMATE SIZE 8 X 5', 13-20-520 AND 13-20-550 | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID. SIGN NOT POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2012. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR ENCLOSED PORCH AT (2) - FURNACE ENCLOSURE; FURNACE AND WATER HEATER INSTALLED WITH OUT A PERMIT | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | REAR ENCLOSED PORCH AT (2) HEATING PLANT ENCLOSURE IS MISSING A CEILING. PLANS AND PERMIT REQUIRED FOR THE CONSTRUCTION OF HEATING PLANT ENCLOSURE | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | REAR ENCLOSED PORCH - PROVIDE CLASS - B FIRE DOOR WITH COMPLETE ASSEMBLE FOR HEATING PLANT ENCLOSURE. PLANS AND PERMIT REQUIRED FOR FIRE DOOR INSTALLATION. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2012. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, INTERIOR CONDITIONS AND COMPLIANCE OF PREVIOUS VIOLATIONS OF DATE OF INSPECTION 03/16/2009. - 20013 | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | 2ND FLOOR, REAR ENCLOSED PORCH, DAMAGE SIDING, FALLING OFF | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | REAR EGRESS FROM BUILDING, PROVIDE REAR SECOND EGRESS FROM APARTMENTS, MASONRY GARAGE IS BLOCKING REAR EGRESS | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PERMIT REQUIRED - CONTRACTOR | REAR ENCLOSED PORCH AT (2) - FURNACE ENCLOSURE; FURNACE AND WATER HEATER INSTALLED WITH OUT A PERMIT | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | REAR ENCLOSED PORCH AT (2) HEATING PLANT ENCLOSURE IS MISSING A CEILING. PLANS AND PERMIT REQUIRED FOR THE CONSTRUCTION OF HEATING PLANT ENCLOSURE | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
HEATING PLANT/BOILER ROOM DOOR | REAR ENCLOSED PORCH - PROVIDE CLASS - B FIRE DOOR WITH COMPLETE ASSEMBLE FOR HEATING PLANT ENCLOSURE. PLANS AND PERMIT REQUIRED FOR FIRE DOOR INSTALLATION. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | REAR EGRESS FROM BUILDING, PROVIDE REAR SECOND EGRESS FROM APARTMENTS, MASONRY GARAGE IS BLOCKING REAR EGRESS | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | REAR INTERIOR STAIRWAY, SMOKE DETECTORS - MISSING COVER AND BATTERY.2ND FLOOR HALLWAY SMOKE DETECTOR - FAILED TEST. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY, 3RD FLOOR - MISSING SMOKE DETECTOR. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | ALL ROOMS - NO RESPONSE, UNABLE TO VERIFY DETECTORS AND INTERIOR CONDITIONS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR STAIR SYSTEM | FRONT INTERIOR STAIRWAY, 1ST TO 2ND - MISSING HANDRAIL SECTION. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - LARGE VERTICAL GAP BETWEEN FACE BRICK AND STONE FACADE.EAST ELEVATION AT GRADE - LOOSE PARGING COAT, SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PARAPET | WEST ELEVATION PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR MASONRY GARAGE CONSTRUCTED FROM LOT LINE TO LOT LINE WITHOUT SUBMITTING PLANS AND OBTAINING PERMIT. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID. SIGN NOT POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2012. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | 2ND FLOOR, REAR ENCLOSED PORCH, DAMAGE SIDING, FALLING OFF | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR FLOOR | REAR FLOOR AT BASEMENT / FLOOR HAS A LARGE HOLE THAT IS COVERED WITH PLYWOOD. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | 3RD FLOOR AT REAR / 2 SLEEPING ROOMS / ROOM TEMPERATURES 57F AT TIME OF INSPECTION. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. CB132016 - HEAT DWELLING UNIT ADEQUATELY (14X-8-802.2, 14X-8-802.2.1 AND14X-8-802.2.2) | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | REAR EXIT DOOR AT GRADE - LOCKED WITH DOUBLE KEY LOCK, TENANTS HAVE NO ACCESS TO REAR EXIT DOOR. 3RD FLOOR CENTER DOOR LEADING FROM KITCHEN - LOCKED AT TIME OF INSPECTION. REAR TENANT NEEDS TO BANG ON DOOR FOR ANOTHER TENANT TO OPEN THE DOOR FORM HIM ( DANGEROUS AND HAZARDOUS ). | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
UNAPPROVED HEATING DEVICE | 3RD FLOOR AT CENTER SLEEPING ROOM / TENANT - USING ELECTRIC SPACE HEATER. CB132026 - PORTABLE ELECTRIC SPACE HEATERS (14X-7-705.4)WHERE NOT PROHIBITED BY OTHER SECTIONS OF THE CHICAGO CONSTRUCTION CODES, PORTABLE, ELECTRICSPACE HEATERS MAY BE USED IN ALL OCCUPANCIES IN ACCORDANCE WITH SECTIONS 14X-7-705.4.1 THROUGH14X-7-705.4.4. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
REPAIR/REPLACE SMOKE DETECTORS | BUILDIANG AT VARIOUS LOCATIONS / SMOKE DETECTORS - MISSING. CB197019 - SMOKE ALARMS / DETECTORS - INSTALL (14X-5-504.8, 14X-5-504.8.4,14B-9-907.2.10.1 THROUGH 14B-9-907.2.10.7, AND 14R-11-1104) | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR DOOR HARDWARE | BUILDING 'S FRONT ENTRY DOOR - DOES NOT LATCH, ANYONE CAN GAIN ENTRY TO INTERIOR OF BUILDING. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | REAR EXIT DOOR AT GRADE - DOUBLE KEYED LOCKED AT TIME OF INSPECTION ( DANGEROUS AND HAZARDOUS ). | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
WINDOW REPAIR FOR AIR SEEPAGE | TOP FLOOR / REAR SLEEPING ROOM - BROKEN WINDOW WITH AIR SEEPAGE. CB104075 - WINDOW REPAIR FOR AIR SEEPAGE (14X-3-303.13 AND 14X-12-1202.4.3.3) | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF COMMERCIAL SPACE AND MOST ILLEGAL SLEEPING ROOMS - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
REMOVE | EAST ELEVATION BETWEEN BUILDINGS / CONCRETE BLOCK WALL HAS BEEN PARTIALLY BUILT BLOCKING EGRESS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
SUPPLY HOT WTR MIN TEMP 120DEG | 3RD FLOOR AT REAR KITCHEN / HOT WATER SUPPLIED AT ONLY 60F AT TIME OF INSPECTION. CB154027 - HOT OR TEMPERED WATER - PROVIDE (14X-9-905.2, 14X-9-905.2.1AND 14X-9-905.5) | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | REAR EGRESS FROM BUILDING IS THROUGH GARAGE, EGRESS IS INTO NEIGHBORS PROPERTY, PROVIDE REAR SECOND EGRESS FROM APARTMENTS, MASONRY GARAGE IS BLOCKING ORIGINAL REAR EGRESS. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - LARGE VERTICAL GAP BETWEEN FACE BRICK AND STONE FACADE.EAST ELEVATION AT GRADE - LOOSE PARGING COAT, SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | NORTH ELEVATION FACADE SHIFTING OUT TOWARD PUBLICWAY. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION ABOVE COMMERCIAL STORE FRONT WINDOW FACADE SHIFTING OUT ONTO PUBLICWAY.(PERMIT REQUIRED FOR REPAIRS). | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR MASONRY GARAGE CONSTRUCTED FROM LOT LINE TO LOT LINE WITHOUT SUBMITTING PLANS AND OBTAINING PERMIT. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
CONTRARY TO ORIGINAL PLAN | THE REAR ENCLOSED PORCH HAS INSUFFICIENT FIRE RESISTIVE WALL COVERING WITH SEAMS THAT ARE NOT SEALED AND NUMEROUS OPEN HOLES IN THE COVERING FROM GRADE TO THE 3RD FLOOR. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
1HR PUB.CORIDR NON-RES/SPRNKLD | ALL 3 LEVELS OF EXIT CORRIDORS ARE EITHER WOOD LATH / PLASTER OR 3/8" DRYWALL. THERE MUST BE AT LEAST 1 HOUR (5/8") FIRE RATED WALL AND CEILING COVERING FOR ALL EXIT CORRIDORS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
FIRE EXTNGSHR REQ, RESDNTL | THERE ARE NO UL APPROVED / DATE LABLED FIRE EXTINGUISHERS IN THIS SRO. DANGEROUS AND HAZAROUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
1-HR HEATING PLANT ENCLOSURE | NONE OF THE MULTIPLE FORCED AIR FURNACES USED TO HEAT THIS SRO HAVE A 1 FIRE FIRE RATED ENCLOSURE. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR ENCLOSED PORCH ... 3 STORIES. THE STRUCTURAL SUPPORT COLUMNS ARE ALL SEVERELY OVER NOTCH CUT. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | THE BUILDING LOCATED AT 3793 S. ARCHER AVE. IS AN ANNUALLY INSPECTED BUILDING BY THE CITY OF CHICAGO DEPT. OF BUILDINGS. DURING THE ANNUAL INSPECTION OF 8/22/18 IT WAS OBSERVED THAT THE ORIGINAL CONSTRUCTION AND OCCUPANCY (1 COMMERCIAL UNIT AND 3 DWELLING UNITS) HAS BEEN CHANGED TO THE NOW EXISTING (UNLICENCED SRO WITH 26 ROOMING UNITS AND AN UNLICENCED MASSAGE PARLOR). THERE ARE NO COMPREHENSIVE PLANS OR THE REQUISITE PERMITS ON FILE FOR THE EXTENSIVE CONSTRUCTION AND OCCUPANCY ALTERATIONS THAT HAVE OCCURED. THIS OCCUPIED SRO HAS NO SYSTEM III EMERGENCY LIGHTING SYSTEM OR A FIRE CONTROL SYSTEM LINKED WITH THE CHICAGO FIRE DEPARTMENT. THE CHANGE OF OCCUPANCY TO AN SRO REQUIRES AN EXTENSIVE UPGRADE IN FIRE PROTECTED CORRIDORS, DOORS AND STAIR SYSTEMS. NONE OF THE PROVISIONS OUTLINED IN THE CITY OF CHICAGO'S BUILDING CODE REGARDING SRO'S HAS BEEN ADHERED TO. THERE HAS BEEN NO ZONING AUTHORIZATION NOR HAS A CERTIFICATE OF OCCUPANCY BEEN OBTAINED. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQUIRED | THE BUILDING LOCATED AT 3793 S. ARCHER AVE. IS AN ANNUALLY INSPECTED BUILDING BY THE CITY OF CHICAGO DEPT. OF BUILDINGS. DURING THE ANNUAL INSPECTION OF 8/22/18 IT WAS OBSERVED THAT THE ORIGINAL CONSTRUCTION AND OCCUPANCY (1 COMMERCIAL UNIT AND 3 DWELLING UNITS) HAS BEEN CHANGED TO THE NOW EXISTING (UNLICENCED SRO WITH 26 ROOMING UNITS AND AN UNLICENCED MASSAGE PARLOR). THERE ARE NO COMPREHENSIVE PLANS OR THE REQUISITE PERMITS ON FILE FOR THE EXTENSIVE CONSTRUCTION AND OCCUPANCY ALTERATIONS THAT HAVE OCCURED. THIS OCCUPIED SRO HAS NO SYSTEM III EMERGENCY LIGHTING SYSTEM OR A FIRE CONTROL SYSTEM LINKED WITH THE CHICAGO FIRE DEPARTMENT. THE CHANGE OF OCCUPANCY TO AN SRO REQUIRES AN EXTENSIVE UPGRADE IN FIRE PROTECTED CORRIDORS, DOORS AND STAIR SYSTEMS. NONE OF THE PROVISIONS OUTLINED IN THE CITY OF CHICAGO'S BUILDING CODE REGARDING SRO'S HAS BEEN ADHERED TO. THERE HAS BEEN NO ZONING AUTHORIZATION NOR HAS A CERTIFICATE OF OCCUPANCY BEEN OBTAINED. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
PROVIDE | THERE ARE INSUFFICIENT EXIT DOORS USED AT THE FRONT AND REAR CORRIDORS AS WELL AS THE GRADE LEVEL FRONT / REAR BUILDING ENTRANCE DOORS.THEEXISTING DOORS ARE NOT LABLED "CLASS B": WHICH IS THE DESIGNATION FOR 90 MINUTE FIRE RATED DOORS. THERE IS NO FIRE DOOR AT THE 2CD FLOOR FRONT EXIT CORRIDOR. TO BE CLEAR, ALL COORIDOR AND STAIRWELL DOORS MUST BE FIRE RATED / LABLED CLAS B FIRE DOORS. SECTION 15-8-160.ALSO, THERE ARE NO EXIT DIAGRAMS IN PLACE AND THESE MUST BE PROVIDED PER SECTION 15-4-881.ALSO. THERE ARE NO SELF CLOSING DEVICES ON THE EXISTING, SUBSTANDARD ARRAY OF DOORS. THESE DEVIVES MUST BE PROVIDED ON THE INSTALLATION IF EVERY NEW CLASS B FIRE DOOR AND ON EACH AND EVERY ROOMING UNIT DOOR. SECTION 13-196-170 AND 18-8-240. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | THE FRONT STAIRWELL ENCLOSURE FROM GRADE TO THE 3RD LEVEL IS WOOD LATH AND PLASTER. THE REAR ENCLOSED PORCH FRAMING (WALLS) ARE SHEATHED WITH 3/8" DRYWALL. PROVIDE AT LEAST 1 HOUR FIRE RESISTIVE WALL COVERING AND SEAL ALL SEAMS TO BOTH THE FRONT AND REAR STAIR SYSTEMS. THE LACK OF FIRE PROTECTION AT THESE STAIR ENCLOSURES IS TO BE CONSIDERED DANGEROUS AND HAZARDOUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | THE REAR ENCLOSED PORCH DECKS AND STAIRWELL UNDERSIDES ARE OPEN / EXPOSED WOOD FRAMING WITH ABSOLUTELY NO FIRE RATED PROTECTION. DANGEROUS AND HAZARDOUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
ILLUMINATE PUBLIC STAIR/HALL | AT THE TIME OF INSPECTION THERE WAS NO SYSTEM III EMERGENCY LIGHTING SYSTEM IN PLACE AT THE EXIT CORRIDORS OR EXIT STAIRWELLS. THE EXISTING LIGHTING IS INSUFFICIENT WITH TOO FEW LIGHTS AND NUMEROUS INOPERABLE LIGHT FIXTURES. NONE OF THE EXISTING LIGHT FIXTURES ARE FIRE RATED AND DO NOT HAVE SUFFICIENT LUMEN RATING TO PROVIDE SUFFICIENT ILLUMINATION. DANGEROUS AND HAZARDOUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | THIS UNLICENCED SRO, WHICH HAS NO FIRE ALARM SYSTEM REQUIRED BY CODE, HAS ONLY 1 SMOKE DETECOR ON THE 1ST FLOOR REAR AREA. THERE ARE NO SMOKE DETECTORS IN THE STAIRWELLS, THE EXIT CORRIDORS OR THE ROOMING UNITS. DANGEROUS AND HAZARDOUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
CARB MONOX DETECT IN RESID | THERE IS ONLY 1 CARBON MONOXIDE DETECTOR AT THE 1ST FLOOR REAR EXIT CORRIDOR. NONE OF THE ROOMING UNITS ARE EQUIPPED WITH A C.O. DETECTOR. THE HEAT PLANT USES GAS FIRED FURNACES AS WELL AS GAS STOVES ON EACH FLOOR. DANGEROUS AND HAZARDOUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
INSTALL EXIT SIGN | THE DIRECTIONAL SIGNAGE IN PLACE IS NOT FIRE RATED. ALL OF THE EXISTING DIRECTIONAL SIGNAGE IS INOPERABLE. ALL NEW, FIRE RATED DIRECTIONAL SIGNS ARE REQUIRED. DANGEROUS AND HAZAROUS. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
MAINTAIN EXIT SIGN ILLUMINATED | ALL EXISTING DIRECTIONAL SIGNS ARE INOPERABLE. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
BUILDING IN DISREPAIR | THIS UNLICENED SRO IS EITHER SEVERELY BELOW MININMUM CODE REQUIREMENTS OR NOT CODE COMPLIANT AL ALL IN SO MANY LIFE SAFELY CATEGORIES THAT THIS BUILDING AS A WHOLE MUST BE CONSIDERED DANGEOUS AND HAZARDOUS. THERE IS ONE WORKING SMOKE DETECTOR IN THIS 26 UNIT SRO. THERE ARE NO AUTOMATIC FIRE DETECTORS. THERE IS NO CLASS 1 FIRE ALARM SYSTEM. THERE IS NO SPRINKLER SYSTEM IN LIEU OF THE CLASS 1 FIRE ALARM SYSTEM.THERE IS NO ON SITE MANAGER. THE SANITATION FACILITIES (UNDER THE PLUMBING CODE) ARE NOT SUFFICIENT. THERE HAS BEEN NO CERTIFICATE OF OCCUPANCY INSPECTION. NO PLANS OR PERMITS WERE SUBMITTED FOR THE CHANGE TO A SRO. THE LIKELIHOOD OF UNLICENCED PERSONELL HAVING PERFORMED ELECTRICAL AND PLUMBING WORK IS HIGH DUE TO THE POOR WORKMANSHIP OBSERVED. THERE ARE DANGEROUS AND HAZARDOUS EGRESS ISSUES.IF ZONING AUTHORIZATION IS GIVEN AND PERMITS ARE OBTAINED, IT WOULD REQUIRE VACATING PORTIONS OF THIS SRO DURING CONSTRUCTION. THE BUILDING IS CURRENTLY WITHOUT PLANS, PERMITS OR A LICENCE AND IS IN DANGEROUS AND HAZARDOUS CONDITION. BASED ON THESE PROFOUND LIFE SAFETY CODE ISSUES IT WOULD BE PRUDENT TO VACATE THIS PROPERTY AS SOON AS POSSIBLE. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, INTERIOR CONDITIONS AND COMPLIANCE OF PREVIOUS VIOLATIONS OF DATE OF INSPECTION 03/16/2009. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | THE 3RD FLOOR, WHICH CONTAINS 8 OCCUPIED ROOMING UNITS, HAS NO FRONT EXIT. THERE IS ACCESS ONLY TO THE REAR ENCLOSED PORCH. THIS IS AN EXTREMELY DANGEROUS AND HAZARDOUS CONDITION. VACATING THIS 3RD FLOOR SET OF ROOMING UNITS MUST BE A LIFE SAFETY CONSIDERATION. | 3793 S ARCHER AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - OWNER'S ID. SIGN NOT POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - NOT REGISTERED YEARS 1990 THRU 2012. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | 2ND FLOOR, REAR ENCLOSED PORCH, DAMAGE SIDING, FALLING OFF | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION ABOVE COMMERCIAL STORE FRONT WINDOW FACADE SHIFTING OUT ONTO PUBLICWAY.(PERMIT REQUIRED FOR REPAIRS). | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PROTECT SIDEWALK DURING CONST | NORTH ELEVATION FACADE SHIFTING OUT TOWARD PUBLICWAY. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
INSUFFICIENT MEANS OF EGRESS | REAR EGRESS FROM BUILDING IS THROUGH GARAGE, EGRESS IS INTO NEIGHBORS PROPERTY, PROVIDE REAR SECOND EGRESS FROM APARTMENTS, MASONRY GARAGE IS BLOCKING ORIGINAL REAR EGRESS. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING - NO OWNER'S ID SIGN POSTED. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
CHIMNEY | CHIMNEY - WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
BUILDING IN DISREPAIR | UNLICENSED SRO SEVERELY BELOW MINIMUM REQUIREMENTS. THIS BUILDING IS DANGEROUS AND HAZARDOUS.MISSING ALL REQUIREMENTS FOR SRO. EXTENSIVE SUBSTANDARD UNPERMITTED ALTERATIONS. MISSING OR INOPERABLE DETECTORS NO FIRE PANEL OR ONSITE MANAGER | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
1-HR STAIR ENCLOSURE, <3 STORY | PROVIDE PROPER FIRE RATINGS AT STAIRWELLS FRONT AND REAR | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
WARNING IF WORK PERMITTED | PROPERTY NOT ZONED FOR USE AS SRO | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR MASONRY GARAGE CONSTRUCTED FROM LOT LINE TO LOT LINE WITHOUT SUBMITTING PLANS AND OBTAINING PERMIT. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PROVIDE | PROVIDECLASS B FIRE RATED SELF CLOSING DOORS AT STAIRWELLS AND CORRIDORS PER SECTION 15-8-160EXIT DIAGRAMS PER 15-4-881 | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR UNPERMITTED ALTERATIONS AND CHANGE OF USE FROM MIXED USE COMMERCIAL/RESEDENTIAL TO COMMERCIAL/SRO. INCLUDE ON PLANS ALL REQUIREMENTS FOR SRO. INCLUDING FIRE EMERGENCY PANEL,EMERGENCY LIGHTING,FIRE RATINGS, HARDWIRED DETECTORS ETC. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
PARAPET | WEST ELEVATION PARAPET WALL - SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
REPAIR EXTERIOR WALL | NORTH ELEVATION - LARGE VERTICAL GAP BETWEEN FACE BRICK AND STONE FACADE.EAST ELEVATION AT GRADE - LOOSE PARGING COAT, SPALLING BRICKS AND WASHED OUT MORTAR. | 3793 S ARCHER AVE | PERIODIC | FAILED | View |
UNDERSIDE STAIR 1HR FIRE RES | PROVIDE PROPER FIRE RATING AT REAR STAIRS | 3793 S ARCHER AVE | PERIODIC | FAILED | View |