The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
MAINTAIN EXIT SIGN ILLUMINATED | 1ST TO 3RD FL / EXIT LIGHT - MADE OF PVC | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS-FLIGHTS SHIFT FROM SIDE TO SIDE UPON LOAD. LOOSE RAILS. MOST MEMBERS ARE ONLY TOE NAILED TOGETHER AT THE CONNECTIONS. PLANS AND PERMIT REQUIRED FOR REPAIRS. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
INSECTS | BUILDING-BEDBUG INFESTATION THROUGHOUT. PROPERTY MUST BE EFFECTIVELY TREATED TO EXTERMINATE BEDBUGS THROUGHOUT, BY EMPLOYING AN EXPERIENCED EXTERMINATOR IN ABATEMENT OF BEDBUG INFESTATION. BUILDING DEPARTMENT WILL NOT CONSIDER THIS VIOLATION COMPLIED WITHOUT PROOF OF SAID EXTERMINATION. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID SIGN NOT POSTED. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
OBSTRUCTIONS IN EXIT WAY | PADLOCKED. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS SET ON CONCRETE - FOUNDATION STATUS UNKNOWN. 2 - 6" X 6" COLUMNS RISE 25' WITHOUT INTERMEDIATE BEAMS.COLUMNS ARE BOWED. 2ND AND 3RD FLOOR LANDINGS SWAY NOTICEABLY. BEAMS ATTACHED TO COLUMNS WITH NAILS ONLY. RIM JOISTS ATTACHED TO COLUMNS AND POSTS WITH NAILS ONLY. STRINGERS ATTACHED TO COLUMNS AND POSTS WITH NIALS ONLY. 42" RAIL ATTACHE DTO EXTERIRO WALL, COLUMNS AND POSTS WITH NAILS ONLY. PLANS AND PERMIT REQUIRED TO REPAIR OR REPLACE PORCH. | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR FLOOR | 1ST FL NEAR KITCHEN /WOOD FLOOR - LIFTING UP | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
INSTALL DOOR VIEWING DEVICE | 1ST TO 3RD FL / VIEWING DEVICE - INTERIOR BED ROOMS DOOR MISSING . | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
CHIMNEY CAPPING | CENTER / CHIMNEY CAP - MISSING | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | FRONT / EXTERIOR PORCH - GRADE TO 1ST FL .1ST AND LAST RISER UNDERSIZED AND OVER SIZED .IRON GUARDRAILS RUSTED .WOODEN GUARDRAILS OVER SPAN AND WEAK .GUARD RAILS TOP BOTTOM RAILED TOE NAILED ONLY .1ST FL LANDING PLYWOOD USED FOR DECKING REAR/ EXTEROR PORCH - GRADE TO ATTIC.1ST RISER 12 INCHES .1ST FL HEADER BY 6X6 CRACKED . 2ND FL LEDGER BOARD MISSING BOLTS . TOP MID LANDING SWAYING .TOP LANDING NALS LOOSE BY TOP AND BOTTOM RAILS . PERMIT REQUIRD TO REPAIR FRONT AND REAR PORCHES | 7143 S HARVARD AVE | COMPLAINT | FAILED | View |