The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | SR#800283467-OWNER'S I.D SING IS NOT POSTED | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT GATE-DOUBLE KEYED CYLINDER LOCK | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR-MISSING GUARD RAIL AT BASEMENT AREAWAY | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | THREE STORY BRICK AND WOOD FRAME CONSTRUCTION BUILDING.EAST AND SOUTH ELEVATION ALL LEVELS - VERTICAL EXTERIOR CRACKS. 1ST AND 3RD FLOOR APTS. - VERTICAL INTERIOR CRACKS OBSERVED IN THE SOUTH AND EAST EXTERIOR WALLS ALSO IN THE CEILING. ( CRACKS OBSERVED IN THE WALLS AND CEILING PLASTER ).PLANS AND PERMIT ARE REQUIRED FOR ALL STRUCTURAL BUILDING REPAIRS. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
SUBMIT 2 COPY STRUCTURAL RPT | THREE STORY BRICK AND WOOD FRAME CONSTRUCTION BUILDING, EAST AND SOUTH ELEVATIONS ALL LEVELS - VERTICAL EXTERIOR CRACKS.1ST AND 3RD FLOOR APTS - VERTICAL INTERIOR CRACKS OBSERVED IN THE SOUTH AND EAST EXTERIOR WALLS AND ALSO IN THE CEILINGS. ( CRACKS OBSERVED IN THE WALLS AND CEILING PLASTER ).PROVIDE STRUCTURAL ENGINEERING REPORT INDICATING THE STRUCTURAL STABILITY OF THIS THREE STORY MASONRY AND WOOD FRAME CONSTRUCTION BUILDING. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR INTERIOR WALLS/CEILING | FRONT INTERIOR STAIRWAY, 3RD FLOOR CEILING - EXPOSED WOOD LATH.1ST AND 3RD FLOOR APTS. LIVINGROOM AND DINNING ROOMS PLASTER HAS LARGE CRACKS. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR THREE STORY PORCH, COLUMNS ERECTED O TOP OF RETAINING WALL WITH NO BASES; FOUNDATION STATUS UNKNOWN.COLUMNS ARE STACKED ON TOP 6"X6" BEAMS.UNDERSIZED 6"X6" BEAMS SPAN 6'-10-1/2".UNDERSIZED 2"X8" DECK JOISTS SPAN 11'-7".STRINGERS ARE FASTENED TO 4"X4" RAILING POSTS WITH NAILS ONLY.GUARD RAILING SECTION ON THE 3RD FLOOR IS ONLY 35" HIGH. AL OTHER GUARD RAILING SECTIONS ARE LOOSE AND PULLING ( BOTTOM) WITH BROKEN PICKETS ON THE 2ND FLOOR. GUARD RAILINGS ARE FASTENED TO EXTERIOR WALLS WITH NAILS ONLY.GUARD AND HAND RAILING SECTIONS ARE ONLY TOE NAILED TO 4"X4" RAILING POSTS AND COLUMNS.ROOF - MISSING HATCH COVER.PLANS AND PERMIT ARE REQUIRED TO REPAIR PORCH SYSTEM. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | SOUTH AND WEST SERVICE WALK - CRACKED AND SECTIONS MISSING CONCRETE. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
INSTALL SMOKE DETECTORS | FRONT INTERIOR STAIRWAY - MISSING SMOKE DETECTOR. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | INTERIOR ALTERATIONS OF EXISTING 3 STORY MASONRY BUILDING INCLUDING BUT NOT LIMITED TO:REMOVED PARTITIONS FROM FIRST SECOND AND 3RD FLOOR. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
ARRANGE COMPLETED PERMIT INSP. | 1644 N KEDZIE AVE | PERMIT | FAILED | View | |
PROVIDE | BUILDING-MISSING DOOR BELL | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
INSTALL EXTRA SMOKE DETECTORS | 3RD FLOOR APT. INSTALL ADDITIONAL SMOKE DETECTOR NEAR THE FRONT BEDROOMS. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
REPAIR WINDOW SILLS | EAST WINDOW SILLS - WASHED OUT MORTAR. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |
BLANK-TEXT MUST CITE CODE SECT | STOP ALL WORK ON PREMISES UNTIL PLANS ARE APPROVED AND PERMIT IS OBTAINEDSECTION 12-080, 13-32-035. | 1644 N KEDZIE AVE | COMPLAINT | FAILED | View |