Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
18-27-210.8 INSTALL GFCI'S IN WET LOCATIONS IN KITCHEN AND BASEMENT. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View | |
PRV BALLCOCK,VB,OR AIR GAP | MISSING SILCOCK WEST ELEVATION. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR DOWNSPOUT | SOUTH ELEVATION DOWN SPOUT DISCONNECTED FROM GUTTER. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR/REBUILD GARAGE OR SHED | GARAGE MISSING SERVICE DOOR AND JAMB. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | REAR DECK/STAIRS ERECTED WITHOUT PLANS AND PERMIT. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR PLATFORM | REAR DECK COLUMNS ERECTED ON PAVEMENT , BEAM TO COLUMN CONNECTIONS ARE ONLY NAILED, MISSING LEDGER BOLTS, 2X8 JOISTS ARE OVER SPANNED AT OVER 8 FEET, HORIZONTAL PICKETS AT GUARD RAIL CREATE A LADDER EFFECT. PLANS AND PERMITS ARE NEEDED FOR REPAIRS. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | REAR EXTERIOR STAIRS STRINGERS ARE OVER CUT, MISSING TREAD RISERS, MISSING PICKETS AT DECK SIDE RAIL. IMPROPER HORIZONTAL PICKETS. FRONT STAIRS MISSING HAND RAIL. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
SERVICE WALK, PASSAGE, AREAWAY | FRONT SERVICE WALK FRACTURED AND SHIFTED CONCRETE. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | NO ENTRY TO BASEMENT OR ATTIC. UNABLE TO VERIFY OCCUPANCY, DETECTORS AND CONDITIONS. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
PROPER MATRL WATER SUPPLY PIPE | REMOVE FLEX SUPPLIES TO KITCHEN FAUCET, LAVATORY AND TOILET 1ST FLOOR. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
PROVIDE AIR CHAMERS | PROVIDE AIR CHAMBERS ON HOT AND COLD WATER SUPPLIES TO KITCHEN FAUCET 1ST FLOOR. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
VENT SYSTEM TO PRVNT BACK PRES | NO VENT ON KITCHEN WASTE 1ST FLOOR. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
INSTALL ILLUMINATION | INSTALL ILLUMINATION TO ALL EXTRIOR ENTRY DOORS INCLUDING GARAGE DOOR. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
CHIMNEY | SOUTH ELEVATION CHIMNEY OPEN MORTAR JOINTS. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |
13-12-360. PROVIDE PERMIT TO CORRECT VIOLATIONS. | 6047 N FAIRFIELD AVE | COMPLAINT | FAILED | View |