Last Modification Date: 2024-08-30 @ 5:15 PM
PIN: 12111190060000
Property Address: 5348 N CUMBERLAND AVE
City - Zip: CHICAGO - 60656
2023 Property Class:
2023 Township: -
2023 Neighborhood:
2023 Tax District:
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 87 Violations
Violation Inspector Comments Address Category Status View
REPAIR INTERIOR WALLS/CEILING 5358 REAR EXIT VESTIBULE CEILING, PEELING PAINT 5348 N CUMBERLAND AVE PERIODIC PASSED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 2006 THRU 2008. 5348 N CUMBERLAND AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED 2006 THRU 2008. 5348 N CUMBERLAND AVE PERIODIC FAILED View
PROVIDE ACCESS TO PIT PIT LADDER. 5348 N CUMBERLAND AVE PERMIT FAILED View
ILLUMINATE ELEV PIT MOVE PIT LIGHT SWITCH. 5348 N CUMBERLAND AVE PERMIT FAILED View
ENCLOSE ELE H/W 2 HR FIRE PATCH HOISTWAY. 5348 N CUMBERLAND AVE PERMIT FAILED View
ENCLOSE MACH/RM 2 HR FIRE PATCH MACHINE ROOM. 5348 N CUMBERLAND AVE PERMIT FAILED View
INST PROP RACEWAYS FOR WIRING 1.PROVIDE GFGI RECEPTACLE ELEVATOR MACHINE ROOM. 2.PROVIDE HEAVY DUTY FUSED AND LOCKABLE MACHINE DISCONNECTED. 3.PROVIDE FUSED LOCKABLE ROOM LIGHTING. 4.PROVIDE PROTECT MACHINE ROOM LIGHTING. 5348 N CUMBERLAND AVE PERMIT FAILED View
1.PROPERLY REINFORCE TOP OF HOISTWAY OR PROVIDE STRUCTURAL ENGINEERING REPORT STATING HOISTWAY SOUND. 2.PROVIDE FIRE RATED MACHINE ROOM DOOR WITH CLOSER AND SELF LOCKING HANDLE. 3.PROPERLY VENTILATE ELEVATOR MACHINE ROOM. 5348 N CUMBERLAND AVE PERMIT FAILED View
REP/REPL FIRE RECALL PASS FULLY TEST FIREMAN SERVICE RECALL. 5348 N CUMBERLAND AVE PERMIT CLOSED View
REPAIR INTERIOR WALLS/CEILING 1ST FLOOR LOBBY CEILING HOLE 5348 N CUMBERLAND AVE PERIODIC PASSED View
ILLUMINATE PUBLIC STAIR/HALL 1ST FLOOR LOBBY EXIT SIGN NOT LIT 5348 N CUMBERLAND AVE PERIODIC PASSED View
INT WALL/CEILING CHIP PLASTER 1ST FLOOR LOBBY UNFINISHED PLASTER WORK 5348 N CUMBERLAND AVE PERIODIC PASSED View
ARRANGE PREMISE INSPECTION ENTRY REFUSED AT INT APTS-ANNUAL INSP 5348 N CUMBERLAND AVE PERIODIC PASSED View
ENCLOSE ELE H/W 2 HR FIRE PATCH HOISTWAY. 5348 N CUMBERLAND AVE PERMIT FAILED View
OPEN TYPE VIOLATION 1. PROPERLY VENTILATE ELEVATOR MACHINE ROOM. 2. MAKE REPAIRS TO TOP OF ELEVATOR HOISTWAY OR PROVIDE STRUCTURAL ENGINEERES REPORT STATING TOP OF HOISTWAY IS SOUND. 18-30-101, 13-20-12 100208128. 5348 N CUMBERLAND AVE PERMIT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH 3RD FLOOR SUN DECK - NO GUARD RAIL FOR PROPER HEIGHT 42 INCHES (D&H) 5348 N CUMBERLAND AVE PERIODIC PASSED View
REPAIR EAVES 5358 3RD FLOOR SUN DECK AREA EAVES - PEELING PAINT 5348 N CUMBERLAND AVE PERIODIC PASSED View
COVER OUTLETS AND JBS ALL FLOORS - ALL THRU CORRIDORS WALK - ALL OUTLETS - NO COVERS 5348 N CUMBERLAND AVE PERIODIC PASSED View
INSTALL SMOKE DETECTORS ALL CORRIDORS ALL FLOORS NO SMOKE ALARMS 5348 N CUMBERLAND AVE PERIODIC PASSED View
HOLDOPEN DEVICE, STAIR 3+ FLRS ALL THRU CORRIDORS - DOORS - HELD OPEN BY WOOD 5348 N CUMBERLAND AVE PERIODIC PASSED View
REPAIR EXTERIOR WALL 5358-SOUTH ELEVATION,FRONT ENTRY WAY,WING WALLS WITH LOOSE AND MISSING BRICKS.5348-ENTRY WAY WING WALLS,WASHED OUT MORTAR AND FRACTURED MASONRY. 5348 N CUMBERLAND AVE COMPLAINT CLOSED View
REPLCE WINDOW PANES, PLEXGLAS 5348-EAST ENTRY DOOR BROKEN PANE. 5348 N CUMBERLAND AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS 5348-EAST ENTRY DOOR BROKEN PANE. 5348 N CUMBERLAND AVE COMPLAINT CLOSED View
REPAIR EXTERIOR WALL 5358-SOUTH ELEVATION,FRONT ENTRY WAY,WING WALLS WITH LOOSE AND MISSING BRICKS.5348-ENTRY WAY WING WALLS,WASHED OUT MORTAR AND FRACTURED MASONRY. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 5348-EAST ENTRY DOOR BROKEN PANE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION BUILDING NO ENTRY,TO CHECK OCCUPANCY,DETECTORS,ANNUAL AND COMPLAINT OF SR#100443497. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL 5358-SOUTH ELEVATION,FRONT ENTRY WAY,WING WALLS WITH LOOSE AND MISSING BRICKS.5348-ENTRY WAY WING WALLS,WASHED OUT MORTAR AND FRACTURED MASONRY. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPLCE WINDOW PANES, PLEXGLAS 5348-EAST ENTRY DOOR BROKEN PANE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE , UNABLE TO INSPECT INTERIOR STAIRWAYS , UNVERIFIED DETECTORS , OCCUPANCY AND DETECTORS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING - NOT REGISTERED 2006 THROUGH 2012 YEARS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 1. MAKE REPAIRS TO TOP OF HOISTWAY OR PROVIDE STRUCTURAL ENGINEERING REPORTS STATING TOP OF ELEVATOR HOISWAY IS SOUND. 18-30-010, 13-20-120 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 2. PATCH ELEVATOR HOISTWAY. 100.1 ASME A17.1 1996 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 3. PATCH ELEVATOR MACHINE ROOM 2HOUR FIRE RATING NEEDED. 101.1(A) ASME A17.1 1996 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 4. FULLY TEST FIREMANS SERVICE AND HAVE WITNESSED BY CITY OF CHICAGO ELEVATOR INSPECTOR. ASME A17.1 1996 211.3 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 5. PROPERLY VENTILATE ELEVATOR MACHINE ROOM. 101.5B 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 6. STENCIL HOISTWAY SIDE OF LANDING DOORS. BOTH CARS EVERY FLOOR. ASME A17.1 2007 2.29.1 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 7. I.D. INSIDE OF ELEVATOR CABS. BOTH 18-30-2620 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 8. PROVIDE SIGNAGE ON ELEVATOR MACHINE ROOM DOOR. 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 9. PROVIDE CODE DATA TAGS INSIDE ELEVATOR CONTROLLERS. 8.6.1.5 ASME A17.1 2007 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 11. REPACK CYLINDER #1 PASSENGER ELEVATOR ASME A17.1 2007 8.6.5.5.1. 18-30-010, 13-20-120. EV005403 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA 3 FIRE SERVICE KEYS REQUIRED IN FIRE SERVICE KEY BOX. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR DOOR RESTRICTOR - ELEVATOR 2. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR TWO WAY COMMUNICATION (PHONE) - ELEVATOR 1. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR AND MAINTAIN ELEVATOR #2. CAR WAS OUT OF SERVICE AT TIME OF INSPECTION. 5348 N CUMBERLAND AVE PERIODIC FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - POSTED OWNER'S I.D. SIGN INCOMPLETE INFORMATION. MISSING MAILING ADDRESS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR FENCE NORTH PARKING LOT CHAINLINK FENCE , BENT AND LOOSE FABRIC ,POLES AND TOP RAIL . AUTO IMPACT DAMAGED.SOUTH AT EAST YARD , PVC SIX FOOT HIGH YARD FENCE GATE BROKEN OFF . FENCE OVER FIVE FEET TALL REQUIRES PERMIT , NONE ON FILE FOR RECENT PVC FENCE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - WINDOW SCREENS , TORN , LOOSE AND MISSING. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR DEFECTIVE FOUNDATION NORTH AT GARAGE ENTRANCE - CONCRETE RETAINING WALL AT EAST , BROKEN OFF SECTION AT NORTH END, WITH DETERIORATED CONCRETE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
PROVIDE GUARD RAIL 42 IN HIGH NORTH AND WEST ELEVATIONS - GUARDRAILS AT GARAGE ENTRY ON RETAINING WALLS , RUSTED , BENT AND LOOSE . AUTO IMPACT DAMAGED. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR EAVES NORTH AND WEST ELEVATION CANOPY OVER ENTRY DOOR , FLAKING MASONRY COATING. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROVIDE FIRE SERVICE TEST LOGS ON SITE 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR DOOR RESTRICTOR ON #1 ELEVATOR 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROPERLY VENTIATE MACHINE ROOM 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPLACE MISSING CONTROLLER BUTTONS/SWITCHES REQUIRED TO OPERATE ELEVATORS FROM CONTROLLERS- BOTH ELEVATORS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROPERLY VENTILATE MACHINE ROOM (PREVIOUSLY CITED) 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA MAKE REPAIRS TO TOP OF HOISTWAY OR PROVIDE STRUCTURAL ENGINEERING REPORTS STATING TOP OF ELEVATOR HOISWAY IS SOUND (PREVIOUSLY CITED) 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CATEGORY 1 TEST, TAG AND DOCUMENT AS REQUIRED - BOTH ELEVATORS 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING EMERGENCY CAB LIGHTING/ALARM BELL - BOTH ELEVATORS 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING 2-WAY COMMUNICATION (PHONE) IN ELEVATOR - CAB #1 5348 N CUMBERLAND AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA SHOW PROOF OF COMPLIANCE WITH SECTION 8.6.5.8 OF A17.1-2007 (SAFETY BULKHEAD REQUIREMENTS) - BOTH ELEVATORS 5348 N CUMBERLAND AVE PERIODIC PASSED View
MAINTAIN OR REPAIR HYDRO ELEVA SCHEDULE "FINAL" INSPECTION WITH CITY OF CHICAGO & SUBURBAN ELEVATOR FOR ELVATOR MODERNIZATION PERMIT #100208128 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SCHEDULE FINAL INSPECTION FOR ELEVATOR MODERNIZATION WITH CITY OF CHICAGO ELEVATOR BUREAU & SUBURBAN ELEVATOR FOR PERMIT #100208128 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA CLEAN BOTH ELEVATOR PITS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
PARAPET EAST ELEVATION/ ABOVE 5348N/ PARAPET WALL- FRACTURED MASONRY, WITH WASHED OUT MORTAR. NORTH ELEVATION/ PARAPET WALL- BRICKS BULGING OUT. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR LINTELS EAST ELEVATION/ 3RD AND 4TH FLOOR LINTELS- WEAK, AND SAGGING.SOUTH ELEVATION/ AT 4TH FLOOR- LINTELS WEAK,AND SAGGING. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR EAVES SOUTH ELEVATION/ ABOVE 5358N/ EAVES- ROTTING, PEELING PAINT, WITH SAGGING SECTIONS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION/ EXTERIOR WALL AT GRADE- FLAKING MASONRY COATING. 5348 N CUMBERLAND AVE PERIODIC FAILED View
NO POSTED ADDRESS EAST ELEVATION/ POSTED ADDRESS- MISSING NUMBERS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
RESTORE EXIT AND EM 5TH FLOOR STAIRWAYS- EMERGENCY LIGHTING OUT OF SERVICE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REMOVE STAGNANT WATER BSMT SOUTH ELEVATION PARKING LOT ENTRANCE CORRIDOR- STACK WITH BROKEN, AND LEAKING SECTION, WITH STANDING WATER, WITH FOUL AND NOXIOUS ODORS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR SCREENS ALL ELEVATIONS - WINDOW SCREENS , TORN , LOOSE AND MISSING. 5348 N CUMBERLAND AVE PERIODIC FAILED View
ARRANGE PREMISE INSPECTION MOST APARTMENTS- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PROPERLY REPAIR AND MAINTAIN ELEVATOR #2. CAR IS CURRENTLY OUT OF SERVICE. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR MALFUNCTIONING TWO WAY COMMUNICATION (PHONES) IN BOTH ELEVATORS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SCHEDULE FINAL INSPECTION FOR THIS WORK WITH CITY OF CHICAGO ELEVATOR BUREAU. 5348 N CUMBERLAND AVE PERMIT FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA SCHEDULE FINAL INSPECTION OF WORK DONE UNDER PERMIT 100208128 ISSUED TO SUBURBAN ELEVATOR. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA PERFORM CATEGORY 1 TEST. TAG AND DOCUMENT AS REQUIRED - BOTH ELEVATORS. 5348 N CUMBERLAND AVE PERIODIC FAILED View
OPEN TYPE VIOLATION 10. CLEAN OIL FROM ELEVATOR PIT #1 CAR ASME A17.1 2007 8.6.4.7.4 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR STOOP WEST ENTRY AT NORTH END - CONCRETE STOOP FRACTURED , HOLES , TRIP HAZARD. 5348 N CUMBERLAND AVE PERIODIC FAILED View
MAINTAIN OR REPAIR HYDRO ELEVA REPAIR TOP HOSITWAY 5348 N CUMBERLAND AVE PERIODIC FAILED View
FILE BLDG REGISTRATION BUILDING NOT REGISTERED FROM 2006 THRU 2017. 5348 N CUMBERLAND AVE PERIODIC FAILED View
CLASS B DOOR IN STAIRWELL 3RD FLOOR SOUTH INTERIOR STAIRWAY DOOR-CLOSER OUT OF SERVICE. 1W INTERIOR STAIRWAY DOOR- TOO LARGE FOR FRAME [DOESN'T CLOSE]. 5348 N CUMBERLAND AVE PERIODIC FAILED View
STOP/REMOVE NUISANCE SOUTH ELEVATION/ ABOVE 4TH FLOOR- VENT COVER MISSING [BIRDS NESTING]. 5348 N CUMBERLAND AVE PERIODIC FAILED View
REPAIR COPING NORTH ELEVATION/ COPING STONEWORK- FRACTURED, WITH MISSING SECTION. 5348 N CUMBERLAND AVE PERIODIC FAILED View
NO PERMIT WIRING NO PERMIT FOR UG TO SITE LIGHTING + BOXES FOR COURT YARD + POOL AREA 5348 N CUMBERLAND AVE COMPLAINT FAILED View