Viewing Parcel Address (PIN)

More Information

The Open Source Data Files that are here are from Cook County.

This Page is a combination of all Files.

The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.

This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.

The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.

Viewing Parcel Address (PIN)


Last Modification Date: 2024-08-30 @ 4:20 PM
PIN: 13334170230000
Property Address: 4876 W WABANSIA AVE
City - Zip: CHICAGO - 60639
2023 Property Class: 211
2023 Township: 71 - Jefferson
2023 Neighborhood: 71210
2023 Tax District: 71001
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 31 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING/ OWNERS ID SIGN- MISSING. 4876 W WABANSIA AVE COMPLAINT FAILED View
PARAPET SOUTH, AND WEST ELEVATIONS/ PARAPET WALLS- FRACTURED MASONRY, SPALLING BRICKS, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH, AND WEST ELEVATIONS/ EXTERIOR WALLS- FRACTURED MASONRY, SPALLING BRICKS, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
CHIMNEY EAST ELEVATION/ CHIMNEY- SPALLING BRICKS, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
NO KEY TO USE EXIT DOOR FRONT YARD GATE- DOUBLE KEY LOCK. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT STORM DOOR- MISSING KNOB. REAR EXIT DOOR- TOO LARGE FOR FRAME , DRAGS AT BOTTOM. 4876 W WABANSIA AVE COMPLAINT FAILED View
EXPOSED WIRING 1ST FLOOR APARTMENT THRUOUT- EXPOSED WIRES. 4876 W WABANSIA AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS, AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 4876 W WABANSIA AVE COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS, AND FIXTURES [INCLUDING PLUMBING, AND ELECTRIC] INSTALLED IN THE BASMENT WITHOUT A PERMIT. 4876 W WABANSIA AVE COMPLAINT FAILED View
1-HR HEATING PLANT SEPARATION BASEMENT FURNACE ROOM ENCLOSURE- SEPARATED FROM BASEMENT DWELLING UNIT WITH DRY WALL ON ONE SIDE ONLY, WITH EXPOSED WOODEN STUDS. 4876 W WABANSIA AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT INTERIOR STAIRWAY, AND REAR ENCLOSED PORCH- MISSING SMOKE DETECTORS. 4876 W WABANSIA AVE COMPLAINT FAILED View
INT WALL/CEILING PEELING PAINT BASEMENT APARTMENT/ WALLS, AND CEILINGS THRUOUT- MILDEW BUILDUP. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR COPING SOUTH ELEVATION/ COPING STONEWORK- WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED.BL00831 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR LINTELS SOUTH ELEVATION LINTELS - NOTICABLE SIGNS OF RUSTING AND DEFLECTION, PERMIT REQUIRED FOR REPAIRS. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION OFF OF LINTELS - STEP FRACTURES, SHIFTING BRICKS AND WASHED OUT MORTAR.WEST ELEVATION SPALLING BRICKS AND WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION WINDOW SILLS - WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
CHIMNEY CHIMNEY - SPALLING BRICKS AND WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS - TORN WINDOW SCREENS. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRONT ENTRY SCEEN DOOR - MISSING HANDLES. 4876 W WABANSIA AVE COMPLAINT FAILED View
PARAPET SOUTH AND WEST ELEVATION PARAPET WALLS - SPALLING BRICKS AND WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL ALL ELEVATIONS/ EXTERIOR WALLS- FRACTURED, LOOSE, AND SHIFTING MASONRY, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION/ SILLS- LOOSE, SHIFTING MASONRY, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING- NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS. UNABLE TO INSPECT INTERIOR STAIRWAYS. 4876 W WABANSIA AVE COMPLAINT FAILED View
MAINTAIN PROJECTIONS FRONT AND REAR EXTERIOR DOORS/ AWNINGS- WEAK, AND SAGGING SECTIONS. 4876 W WABANSIA AVE COMPLAINT FAILED View
PARAPET & COPING ALL ELEVATIONS/ PARAPET WALLS, AND COPING STONEWORK-FRACTURED, LOOSE AND SHIFTING MASONRY, WITH WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
PERMIT REQUIRED - CONTRACTOR PERMIT IS REQUIRED FOR ALL MASONRY REPAIRS.PERMIT IS SUBJECT TO FIELD INSPECTION, AND APPROVAL. 4876 W WABANSIA AVE COMPLAINT FAILED View
CEILING HEIGHT - 7' - BASEMENT BASEMENT CEILING HEIGHT- ONLY 6 FEET 6 INCHES . 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR SCREENS ALL ELEVATIONS/ WINDOWS- TORN SCREENS. 4876 W WABANSIA AVE COMPLAINT FAILED View
REPAIR WINDOW SILLS SOUTH ELEVATION/ SILLS- WASHED OUT MORTAR. 4876 W WABANSIA AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. NO ENTRY TO BASEMENT TO VERIFY COMPLIANCE OF PREVIOUS VIOLATIONS AND DECONVERSION OF BASEMENT. 4876 W WABANSIA AVE COMPLAINT FAILED View