The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
POST OWNER/MANAGERS NAME/# | (SR#07-01265528, 07-01265532) BUILDING: OWNER'S I.D. SIGN NOT POSTED | 1309 S TROY ST | COMPLAINT | PASSED | View |
NO POSTED ADDRESS | BUILDING: ADDRESS NOT POSTED | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPLCE WINDOW PANES, PLEXGLAS | WEST, NORTH ELEVATIONS: WINDOW PANES ARE BROKEN | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR OR REPLACE | ALL ELEVATIONS: PEELING PAINT ON EXTERIOR SURFACES (SEC. 7-28-060) | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR WALL | WEST ELEVATION: CRACKS, LOOSE BRICKS IN EXTERIOR WALL; NORTH, EAST, SOUTH ELEVATIONS: OPEN JOINTS IN EXTERIOR WALL | 1309 S TROY ST | COMPLAINT | PASSED | View |
MAINTAIN WINDOW | ALL ELEVATIONS: WINDOW FRAMES ARE ROTTING | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPUTTY WINDOW PANES | ALL ELEVATIONS: WINDOW TRIM IS ROTTING | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR WINDOW SILLS | ALL ELEVATIONS: WINDOW SILLS ARE ROTTING | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR FRAME | WEST ELEVATION: FRONT ENTRY DOOR JAMB AND TRIM ARE ROTTING, INTERIOR SIDE OF DOOR IS MISSING TRIM | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | WEST ELEVATION: FRONT ENTRY DOOR IS DENTED, PLYWOOD USED IN LIEU OF SIDE LIGHTS; EAST ELEVATION, BASEMENT: DOOR IS BOARDED UP | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR STAIR | WEST ELEVATION, FRONT: CONCRETE STAIRS ARE CRACKED, SPALLED; EAST ELEVATION: HAND RAIL MISSING FROM GRADE TO BASEMENT | 1309 S TROY ST | COMPLAINT | PASSED | View |
PROVIDE GUARD RAIL 42 IN HIGH | EAST ELEVATION: GUARD RAIL MISSING FOR BASEMENT AREAWAY | 1309 S TROY ST | COMPLAINT | PASSED | View |
NO CLOSET/STORAGE UNDER STAIR | EAST ELEVATION: STORAGE, MATERIALS (DOORS, LUMBER) UNDERNEATH REAR PORCH | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR GUTTER | EAST ELEVATION: HOLE IN GUTTER | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPLACE D&H PORCH | EAST ELEVATION, REAR PORCH: LEDGER BOARDS ARE ATTACHED TO EXTERIOR WALL WITH NAILS ONLY, BEAMS ON 1ST, 2ND FLOOR ARE ROTTING, 6X6 COLUMNS ON 2ND FLOOR IS PULLING AWAY FROM BEAM, INADEQUATE BEAM TO COLUMN CONNECTIONS, STRINGERS ARE INADEQUATELY SUPPORTED AT COLUMNS, STRINGERS ARE PITCHED FORWARD EXCESSIVELY FROM GRADE TO 2ND FLOOR, TREADS ARE LOOSE FROM 1ST TO 2ND FLOOR, RISER HEIGHTS ARE DIFFERENT THRU-OUT, 2X6 JOISTS SPAN OVER 17 FEET, 1ST FLOOR DECKBOARDS ARE LOOSE AT STAIRS, 1ST FLOOR LANDING IS LOOSE AND SHAKY, RAIL HEIHGT IS ONLY 33 INCHES TALL, MISSING ON 1ST FLOOR AND 1ST TO 2ND FLOOR, TOP RAIL IS TWISTED ON 1ST FLOOR; SUBMIT PLANS AND OBTAIN PERMIT FOR REPLACEMENT OF REAR PORCH | 1309 S TROY ST | COMPLAINT | PASSED | View |
PARAPET & COPING | SOUTH ELEVATION: COPING TILES ARWE MISSING AND OPEN JOINTS AT PARAPET WALL | 1309 S TROY ST | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | INTERIOR STAIRWELL: SMOKE DETECTOR IS MISSING | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR HARDWARE | WEST ELEVATION: HARDWARE MISSING AT FRONT ENTRY DOOR. HOLE IS BORED WHERE HARDWARE WAS INSTALLED | 1309 S TROY ST | COMPLAINT | PASSED | View |
INSTALL DOOR VIEWING DEVICE | INTERIOR: VIEWING DEVICES ARE MISSING AT FRONT ENTRY DOORS | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR DOOR, INT. | INTERIOR-1ST, 2ND FLOOR ENTRY DOORS: DOORS ARE DENTED | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR DOOR FRAME, MULLION | INTERIOR-1ST, 2ND FLOOR: TRIM IS MISSING AROUND FRONT ENTRY DOORS | 1309 S TROY ST | COMPLAINT | PASSED | View |
EXPOSED WIRING | INTERIOR-FOYER, STAIRWELL: EXPOSED WIRES AT WALL AND CEILING FIXTURES | 1309 S TROY ST | COMPLAINT | PASSED | View |
SUPPORT FIXTURES | INTERIOR-FOYER, 2ND FLOOR: LIGHT FIXTURES ARE LOOSE AND HANGING | 1309 S TROY ST | COMPLAINT | PASSED | View |
ILLUMINATE PUBLIC STAIR/HALL | INTERIOR FOYER: INADEQUATE ILLUMINATION | 1309 S TROY ST | COMPLAINT | PASSED | View |
PROVIDE DEADLOCK FOR ENTRANCE | WEST ELEVATION: DEADBOLT LOCK MISSING ON FRONT ENTRY DOOR | 1309 S TROY ST | COMPLAINT | PASSED | View |
REPAIR INTERIOR STAIR SYSTEM | INTERIOR STAIRWELL: STAIRS ARE LEANING EXCESIIVELY, TREADS ARE WEAK, 2ND FLOOR DECK IS ROTTING; OBTAIN PERMIT FOR REPAIRS TO INTERIOR STAIR SYSTEM | 1309 S TROY ST | COMPLAINT | PASSED | View |
INT WALL/CEILING CHIP PLASTER | INTERIOR STAIRWELL, 2ND FLOOR: HUGE HOLE IN CEILING WHERE DUCTWORK HAS BEEN INSTALLED | 1309 S TROY ST | COMPLAINT | PASSED | View |
DEFECTIVE METER EQUIPMENT | ILLEGAL TAP AND RUSTED METERS | 1309 S TROY ST | COMPLAINT | PASSED | View |
TENANT ACCESS TO SERVICE | 1309 S TROY ST | COMPLAINT | PASSED | View | |
DEFECTIVE DISTRIBUTION | SPLICES IN PANELS | 1309 S TROY ST | COMPLAINT | PASSED | View |
MULTIPLE CONDUCTOR TERM | 2 BRANCH CIRCUITS TERMINATED UNDER SINGLE BREAKER DANGEROUS AND HAZARDOUS | 1309 S TROY ST | COMPLAINT | PASSED | View |
EXPOSED WIRING | EXTERIOR PORCH'S DANGEROUS AND HAZARDOUS | 1309 S TROY ST | COMPLAINT | PASSED | View |
CONTINUITY OF RACEWAY | EXTERIOR REAR | 1309 S TROY ST | COMPLAINT | PASSED | View |
UNAPPROVED CORDS | LIGHT EXTERIOR REAR CORED WIRING THROUGH WALL AND BASEMENT | 1309 S TROY ST | COMPLAINT | PASSED | View |
PROPER SIZE GRD ELECTRODE COND | ALL PANELS ARC CONNECTED TO GROUND SEPARATELY MULTIPLE GROUND PATHS,IMPROPERLY CONNECTED DANGEROUS AND HAZARDOUS | 1309 S TROY ST | COMPLAINT | PASSED | View |
INSTALL COVERS | BASEMENT DANGEROUS AND HAZARDOUS | 1309 S TROY ST | COMPLAINT | PASSED | View |
CIRCUIT ONE UNIT ONLY | PROVIDE PUBLIC PANEL AND METER TO SERVE BUILDING COMMON AREA LOADS 18-27-210.25 | 1309 S TROY ST | COMPLAINT | PASSED | View |
WORKING SPACE | 3 FEET CLEAR SPACE FRONT OF ELECTRICAL PANELS | 1309 S TROY ST | COMPLAINT | PASSED | View |
OBSTRUCTIONS IN EXIT WAY | NORTH FRONT GATE CHAIN AND PADLOCK | 1309 S TROY ST | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | NO OWNER ID SIGN POSTED | 1309 S TROY ST | COMPLAINT | FAILED | View |
NO KEY TO USE EXIT DOOR | FRONT SOUTH GATE DOUBLE KEY LOCK | 1309 S TROY ST | COMPLAINT | FAILED | View |
REPAIR FENCE | REAR FENCE MISSING TOP POLES | 1309 S TROY ST | COMPLAINT | FAILED | View |
INSPECT CONSTRUCTION WORK | ARRANGE INSPECTOR FOR SIGN OFF ON PERMIT #100266100 | 1309 S TROY ST | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR PORCH - FOUNDATION STATUS UNKNOWN; SPLICE JOINTS IN SAME LOCATION AS BEAM/COLUMN CONNECTIONS AT 2ND FLOOR | 1309 S TROY ST | COMPLAINT | FAILED | View |
DEBRIS, EXCESSIVE | EAST, NORTH ELEVATIONS - TRASH, DEBRIS, JUNK, LEAVES AT BASEMENT AREAWAY UNDERNEATH REAR PORCH AND ON SIDE OF BUILDING | 1309 S TROY ST | COMPLAINT | FAILED | View |
STOP/REMOVE NUISANCE | LAMP, DOOR, LUMBER ON 2ND FLOOR REAR PORCH DECK; ABANDONED VEHICLE ON SIDE OF BUILDING | 1309 S TROY ST | COMPLAINT | FAILED | View |
PROVIDE GUARD RAIL 42 IN HIGH | REAR GUARDRAIL MISSING AT GRADE FOR BASEMENT AREAWAY | 1309 S TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | EXTERIOR WALLS - NORTH - WASHED OUT MORTAR; WEST - PAINT PEELING | 1309 S TROY ST | COMPLAINT | FAILED | View |
REPAIR EXTERIOR STAIR | HANDRAIL MISSING FROM GRADE TO BASEMENT | 1309 S TROY ST | COMPLAINT | FAILED | View |
ARRANGE PREMISE INSPECTION | UNABLE TO INSPECT INTERIOR, STAIRWELLS, APARTMENTS, AND BASEMENT. UNVERIFIED DETECTORS AND OCCUPANCY. | 1309 S TROY ST | COMPLAINT | FAILED | View |
SEE INSPECTOR COMMENTS | SEE NOTICE 9566 | 1309 S TROY ST | PERMIT | PASSED | View |
MAINTAIN WINDOW SASH | ALL ELEVATIONS: WINDOW SASHES ARE ROTTING | 1309 S TROY ST | COMPLAINT | PASSED | View |
COVER OUTLETS AND JBS | INTERIOR STAIRWELL: COVER MISSING AT LIGHT SWITCH | 1309 S TROY ST | COMPLAINT | PASSED | View |
SEE INSPECTOR COMMENTS | 1309 S TROY ST | PERMIT | PASSED | View | |
PERMIT REQUIRED | FENCE OVER 5'FT REQUIRE PERMIT | 1309 S TROY ST | COMPLAINT | FAILED | View |
CUT OR REMOVE HIGH WEEDS | ALL ELECATION HIGH WEED | 1309 S TROY ST | COMPLAINT | FAILED | View |