The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
REPAIR EXTERIOR STAIR | HANDRAIL MISSING. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
REPAIR FLOOR | FLOOR TILES MISSING. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
RATS | RAT CARCASS. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
RAT PROOF OPENINGS | OPENINGS AROUND PIPES. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
ARRANGE PREMISE INSPECTION | 1ST FLOOR, 2ND FLOOR, REAR PORCH, REAR YARD. NO ENTRY. UNVERIFIED DETECTORS AND CONDITIONS. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
POST OWNER/MANAGERS NAME/# | BUILDING OWNER'S ID. SIGN NOT POSTED. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
INSTALL SMOKE DETECTORS | SMOKE DETECTOR MISSING. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
CARB MONOX DETECT IN RESID | CARBON MONOXIDE DETECTOR MISSING. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |
REPLACE DEFECTIVE FLUSH TANK | TOILET INOPERABLE | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
PLANS & PERMITS REQ - CONTRCTR | OBTAIN PLANS AND PERMITS FOR BASEMENT ALTERATIONS INCLUDING PARTITION WALLS,KITCHEN AND BATH,PLUMBING AND ELECTRIC | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
WORK NOT ALLOWED | REMOVE ALL WORK DONE IN BASEMENT WITHOUT PERMIT | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
1HR FLR OVER BSMT, 1 OR 2 DU | 1 HOUR FIRE SEPERATION REQUIRED | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
WINDOW AREA ABOVE GROUND | INSUFFICIENT NATURAL LIGHT AND VENTILATION | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
MICE/RODENTS | EXTERMINATE FOR RODENTS | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | COLUMNS OVERNOTCHED.6X6 BEAMS OVERSPANNED AT 7 FEET.2X8 JOISTS OVERSPANNED AT 12 FEET.STRINGERS UNDERSIZED WITH NO POSITIVE ATTATCHMENT AT LANDINGS.TREADS UNDER 10.5 INCHES.PLANS AND PERMITS REQUIRED FOR REPAIRS. | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
HEAT UNIT ADEQUATELY | NO HEAT PROVIDED 60 DEGREES AT TIME OF INSPECTION | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | POST MANAGEMENT INFO | 1522 S AVERS AVE | COMPLAINT | FAILED | View |
DEFECTIVE OUTLETS | OUTLET DEFECTIVE. | 1522 S AVERS AVE | COMPLAINT | PASSED | View |