Violation Inspector Comments Address Category Status View
STOP/REMOVE NUISANCE (07-01523206) FRONT: HIGH WEEDS (SEC. 7-28-120A; 7-28-060) 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR EXTERIOR STAIR FRONT: RUSTED HANDRAILS 5253 S RICHMOND ST COMPLAINT PASSED View
NO KEY TO USE EXIT DOOR FRONT GATES: DOUBLE KEYED CYLINDER LOCKS 5253 S RICHMOND ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS REAR PORCH: MISSING DETECTOR 5253 S RICHMOND ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS SOUTH: BROKEN PANE AT (B); SOUTH/EAST: MISSING STORM WINDOW PANES 5253 S RICHMOND ST COMPLAINT PASSED View
DEBRIS, EXCESSIVE FRONT/REAR YARDS: ACCUMULATION OF MISCELLANEOUS TRASH, JUNK AND DEBRIS (SEC. 7-28-710; 7-28-720; 7-28-060) 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR FENCE REAR YARD: WOODEN FENCE-MISSING POSTS, BROKEN PICKETS, WEAK AND LEANING; BROKEN REAR GATE 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR/REBUILD GARAGE OR SHED GARAGE: BROKEN PANE, MISSING GUTTERS AND DOWNSPOUT 5253 S RICHMOND ST COMPLAINT PASSED View
PERMIT REQUIRED - CONTRACTOR OBTAIN PERMIT FOR WOODEN CANOPY ATTACHED TO THE GARAGE 5253 S RICHMOND ST COMPLAINT PASSED View
RELOCATE SMOKE DETECTOR APT. 1: DETECTOR IS LOCATED GREATER THAN 12 INCHES DOWN FROM THE CEILING 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR/REPLACE SMOKE DETECTORS ATTIC APT.: OUT OF SERVICE DETECTOR 5253 S RICHMOND ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID APT. 1: MISSING DETECTOR 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR FLOOR APT. 1: KITCHEN/BATHROOM-BROKEN, LOOSE, MISSING FLOOR TILES 5253 S RICHMOND ST COMPLAINT PASSED View
REPLACE DEFECTIVE WASTE PIPING APT. 1, KITCHEN SINK: DRAIN PIPE IS LEAKING 5253 S RICHMOND ST COMPLAINT PASSED View
EXPOSED WIRING REAR PORCH AT GRADE: NORTH WALL-EXPOSED WIRING 5253 S RICHMOND ST COMPLAINT PASSED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS AND FIXTURES, INCLUDING PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT (VIEW THRU OPEN WINDOWS) AND ATTIC WITHOUT A PERMIT 5253 S RICHMOND ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE 5253 S RICHMOND ST COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT DWELLING UNIT: ONLY ONE EGRESS EXISTS (AT THE REAR) 5253 S RICHMOND ST COMPLAINT PASSED View
EGRESS ATTIC DWELLING UNIT: ONLY ONE EGRESS EXISTS (AT THE REAR) 5253 S RICHMOND ST COMPLAINT PASSED View
ARRANGE PREMISE INSPECTION BASEMENT: NO RESPONSE, UNVERIFIED DETECTORS, AND CONDITIONS 5253 S RICHMOND ST COMPLAINT PASSED View
WINDOW REPAIR FOR AIR SEEPAGE 1ST FLOOR APARTMENT/ REAR WINDOW- BROKEN, AND MISSING PANE. 5253 S RICHMOND ST COMPLAINT FAILED View
HEAT UNIT ADEQUATELY BASEMENT APARTMENTS- KITCHEN 51, BEDROOM 49. 1ST FLOOR APARTMENTS- FRONT ROOM 51, MIDDLE BEDROOM 52. ATTIC APARTMENT- BEDROOM 50, KITCHEN 46. HEATING SYSTEM IS OFF AT TIME OF INSPECTION, NO HEAT PROVIDED. GAS SERVICE SHUT OFF. 5253 S RICHMOND ST COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG BASEMENT, 1ST FLOOR, AND ATTIC APARTMENTS- HOT WATER SUPPLIED AT ONLY 43F. GAS SERVICE SHUT OFF. 5253 S RICHMOND ST COMPLAINT FAILED View
CARB MONOX DETECT IN RESID BASEMENT, 1ST FLOOR, AND ATTIC APARTMENTS- MISSING CARBON MONOXIDE DETECTORS. 5253 S RICHMOND ST COMPLAINT FAILED View
WORK NOT ALLOWED REMOVE ALL PARTITIONS, AND FIXTURES [INCLUDING PLUMBING AND ELECTRIC] INSTALLED IN THE BASEMENT, 1ST FLOOR , AND ATTIC WITHOUT A PERMIT. 5253 S RICHMOND ST COMPLAINT PASSED View
PLANS & PERMITS REQ - CONTRCTR SUBMIT PLANS, AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO BASEMENT, 1ST FLOOR, AND ATTIC OR RESTORE THE BUILDING TO THE ORIGINAL STATE. 5253 S RICHMOND ST COMPLAINT PASSED View
EGRESS -BASEMENT BASEMENT DWELLING UNIT- ONLY ONE EGRESS EXISTS [ IN THE REAR]. 5253 S RICHMOND ST COMPLAINT PASSED View
INT WALL/CEILING PEELING PAINT BASEMENT APARTMENT/ WALLS THROUGHOUT- MILDEW BUILDUP. 5253 S RICHMOND ST COMPLAINT PASSED View
REMOVE STAGNANT WATER BSMT BASEMENT APARTMENT- STANDING WATER, WITH RAW SEWAGE. 5253 S RICHMOND ST COMPLAINT PASSED View
REMV OBSTR FROM DRAINAGE SYSTM BASEMENT APARTMENT- ALL DRAINS CLOGGED, AND BACKING UP. 5253 S RICHMOND ST COMPLAINT PASSED View
SUPPLY HOT WTR MIN TEMP 120DEG BASEMENT, AND 1ST FLOOR APARTMENTS- HOT WATER SUPPLIED AT ONLY 43 F. GAS SERVICE SHUT OFF. 5253 S RICHMOND ST COMPLAINT PASSED View
HEATING PLANT SEPARATION BASEMENT FURNACE ROOM ENCLOSURE- SEPARATED FROM BASEMENT DWELLING UNIT WITH DRY WALL ON ONE SIDE ONLY, WITH EXPOSED WOODEN STUDS. 5253 S RICHMOND ST COMPLAINT PASSED View
REPAIR EXTERIOR DOOR HARDWARE REAR EXTERIOR EXIT DOOR- LOCK OUT OF SERVICE. 5253 S RICHMOND ST COMPLAINT PASSED View
OBSTRUCTIONS IN EXIT WAY REAR EXTERIOR EXIT DOOR- LOCK OUT OF SERVICE WITH DOOR UNABLE TO OPEN [HAZARDOUS CONDITION]. 5253 S RICHMOND ST COMPLAINT PASSED View
REPLCE WINDOW PANES, PLEXGLAS EAST ELEVATION/ 1ST FLOOR WINDOW- BROKEN PANE. 5253 S RICHMOND ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS ALL LEVELS, AND STAIRWAYS- MISSING SMOKE DETECTORS. 5253 S RICHMOND ST COMPLAINT PASSED View
CARB MONOX DETECT IN RESID BASEMENT, 1ST FLOOR , AND ATTIC DWELLING UNITS- MISSING CARBON MONOXIDE DETECTORS. 5253 S RICHMOND ST COMPLAINT PASSED View
HEAT UNIT ADEQUATELY BASEMENT, 1ST FLOOR, AND ATTIC DWELLING UNITS- HEAT IS OFF, WITH TEMPERATURES RANGING FROM 46 TO 52 DEGREES F. NO HEAT PROVIDED. 5253 S RICHMOND ST COMPLAINT PASSED View
VACANT BUILDING - REGISTER 5253 S RICHMOND ST COMPLAINT CLOSED View
OBTAIN OR POST PERMIT 5253 S RICHMOND ST COMPLAINT CLOSED View
MAINTAN BLDG IN SAFE CONDITION 5253 S RICHMOND ST COMPLAINT CLOSED View
POST OWNER INFO ON ABDN BLDG 5253 S RICHMOND ST COMPLAINT CLOSED View
REPAIR/WRECK DANGER RESID PREM 5253 S RICHMOND ST COMPLAINT CLOSED View
WATCHMAN 5253 S RICHMOND ST COMPLAINT CLOSED View
REPAIR INTERIOR WALLS/CEILING APT. 1, BATHROOM: WEST WALL IS WATER DAMAGED 5253 S RICHMOND ST COMPLAINT PASSED View
VACANT BUILDING - REGISTER 5253 S RICHMOND ST COMPLAINT CLOSED View
EGRESS ATTIC DWELLING UNIT- ONLY ONE EGRESS EXISTS [IN THE REAR]. 5253 S RICHMOND ST COMPLAINT PASSED View
INSTALL SMOKE DETECTORS BASEMENT, 1ST FLOOR, AND ATTIC APARTMENTS- MISSING SMOKE DETECTORS. 5253 S RICHMOND ST COMPLAINT FAILED View