Chicago Building Violations Data: 81 Violations
Violation Inspector Comments Address Category Status View
REPAIR EXTERIOR WALL OPEN JOINTS, WASHED OUT MORTAR-ALL ELEVATIONS 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR LINTELS RUSTED, BENT, SAGGING LINTELS-EAST & SOUTH ELEVATION 8056 S RACINE AVE COMPLAINT FAILED View
FLAKY INTERIOR PAINT FLAKING PAINT-ALL ELEVATIONS 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM (PERMIT REQUIRED) REAR PORCH, STAIRS: ROTTED STRINGER AT GROUND LEVEL, ROTTED & SPLIT TREADS, 4X4 STAIR COLUMNS-IMPROPER FOOTINGS, 6X6 PORCH COLUMNS-ROTTED & BOWED, BEAM DISCONNECTED AT COLUMN, HANDRAILS LOOSE, GUARDRAILS UNDER 42" , JOIST FLAKING PAINT & WORN-ROOF ELEVATION (GENERAL REPAIRS PERMIT ONLY) 8056 S RACINE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH ROTTED SASHES-VARIOUS LOCATIONS, THRU-OUT 8056 S RACINE AVE COMPLAINT FAILED View
REPUTTY WINDOW PANES VARIOUS LOCATIONS: PUTTY LOOSE & MISSING (WINDOWS) 8056 S RACINE AVE COMPLAINT FAILED View
UNINTERRUPTED EXIT AT GRADE REAR GATES: CHAIN LOCKED 8056 S RACINE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY BURGLAR GATES, ENTRY DOORS, REAR DOORS, THRU-OUT 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR FENCE REAR, SOUTH FENCE: BENT & LOOSE 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR NO HANDRAIL, G TO BASEMENT REAR 8056 S RACINE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH GUARDRAILS, ROOF AREA: ROTTED, LOOSE, UNDER 42" 8056 S RACINE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS FRONT STAIRWELL: NO SMOKE DETECTOR 8056 S RACINE AVE COMPLAINT FAILED View
COVER OUTLETS AND JBS FRONT STAIRWELL: OPEN ELECTRICAL BOX 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING 8056, 2ND FLOOR: LOOSE CEILING TILES, BROKEN PLASTER, DINING ROOM & BEDROOM 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR ROOF 8056, SIDE: ROOF LEAKS INTO 2ND FLOOR APARTMENT 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR 8056, 2ND FLOOR, REAR DOOR: GAPS & DRAFTY 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR FLOOR 8056, 2ND FLOOR: KITCHEN FLOOR TILES BROKEN 8056 S RACINE AVE COMPLAINT FAILED View
REPLACE DEFECTIVE PLBG FIXTURE 8056, 2ND FLOOR: TUB RUSTED, PEELING PAINT 8056 S RACINE AVE COMPLAINT FAILED View
INSTALL DOOR VIEWING DEVICE NO PEEPHOLES, FRONT DOORS 8056 S RACINE AVE COMPLAINT FAILED View
POST OWNER/MANAGERS NAME/# NO MANAGEMENT SIGN POSTED 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL SOUTH ELEVATION AND EAST ELEVATION OPEN MORTAR JOINTS. 8056 S RACINE AVE COMPLAINT FAILED View
MAINTAIN WINDOW 2ND LEVEL APT WINDOWS, FRAMES ROTTING WOOD. 8056 S RACINE AVE COMPLAINT FAILED View
REPUTTY WINDOW PANES 2ND LEVEL APT WINDOWS PUTTY CRACKED AND MISSING. 8056 S RACINE AVE COMPLAINT FAILED View
OBSTRUCTIONS IN EXIT WAY 8058 S. RACINE, APT 25 ENTRY DOOR, AND ENTRY DOOR (EXTERIOR) AS WELL AS REAR GATES - PADLOCKED. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR FLOOR 8058 S. RACINE (GLOBE STORE) FLOOR TILE BROKEN AND MISSING. 8056 S RACINE AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE 8056, 1ST FLR STORE FRONT EXCESSIVE AMT OF TRASH AT FRONT ENTRANCE; REAR YARD TRASH 8056 S RACINE AVE COMPLAINT FAILED View
REPLCE WINDOW PANES, PLEXGLAS ROTTED WINDOW SASHES THROUGHOUT 8056 S RACINE AVE COMPLAINT FAILED View
MAINTAIN WINDOW SASH ROTTED WINDOW FRAMES THROUGHOUT 8056 S RACINE AVE COMPLAINT FAILED View
REPUTTY WINDOW PANES MISSING PUTTY THROUGHOUT 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION - BULGING MASONRY, REAR WALL SEVERELY ERODED MORTAR, LOOSE AND CRUMBLING BRICK WALL IN DANGER OF COLLAPSE, DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
PARAPET & COPING REAR AT NORTH WALL - LOOSE BRICK AND MISSING COPING TILE. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR PORCH SYSTEM REAR PORCH - ROTTED STRINGERS, ROTTED 6X6 COLUMN AT FIRE CUT, STAIRS DO NOT MEET REQUIREMENTS OF CODE SECTION 10(13-160-300), UNEVEN RISERS, PLANS AND PERMIT ARE REQUIRED FOR REPAIRS. 8056 S RACINE AVE COMPLAINT FAILED View
PROVIDE GUARD RAIL 42 IN HIGH ROTTED GUARDRAILS AT REAR BASEMENT STAIRS. 8056 S RACINE AVE COMPLAINT FAILED View
DEBRIS, EXCESSIVE GARBAGE AND DEBRIS AT REAR BASEMENT STAIRS. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR FENCE SOUTH GATE AT REAR OF BUILDING, DAMAGED GATE. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR FLOOR 8058 COMMERCIAL UNIT - DAMAGED AND MISSING FLOOR TILE THROUGHOUT, SECTIONS OF FLOOR THROUGHOUT UNIT DEFLECT SEVERELY AND ARE IN DANGER OF COLLAPSE, DANGEROUS AND HAZARDOUS. UNIT 2N MISSING AND DAMAGED FLOOR TILE. 8056 S RACINE AVE COMPLAINT FAILED View
INT WALL/CEILING CHIP PLASTER 8058 COMMERCIAL UNIT - SEVERE WATER DAMAGE TO ALL WALLS AND CEILINGS; MISSING, LOOSE AND FALLING PLASTER THROUGHOUT. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR INTERIOR WALLS/CEILING UNIT 2N - WATER DAMAGE TO WALL AND CEILINGS THROUGHOUT. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR UNIT 2N, DAMAGED REAR DOOR. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR FRAME UNIT 2N - DAMAGED REAR DOOR JAMB 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR EXTERIOR DOOR, RESET UNIT 2N - REAR DOOR NOT WEATHER TIGHT. 8056 S RACINE AVE COMPLAINT FAILED View
INSTALL SMOKE DETECTORS MISSING SMOKE DETECTORS IN BASEMENT, FRONT STAIRWAY UNIT 2N AND 8058 COMMERCIAL UNIT. 8056 S RACINE AVE COMPLAINT FAILED View
CARB MONOX DETECT IN RESID MISSING CARBON MONOXIDE DETECTORS IN BASEMENT UNIT 2N AND 8058 COMMERCIAL UNIT. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR ROOF SEVERE ROOF LEAK THROUGHOUT 8056 S RACINE AVE COMPLAINT FAILED View
PLANS & PERMITS REQ - CONTRCTR PROVIDE PLANS AND OBTAIN ALL RELATED PERMITS FOR 1) CARPORT IN REAR; 2) ALL VIOLATION REPAIRS; 3) MASONRY REPAIRS. 8056 S RACINE AVE COMPLAINT FAILED View
PROVIDE GUTTER & DOWNSPOUT REAR ONE STORY PORTION OF ROOF HAS STANDING WATER. 8056 S RACINE AVE COMPLAINT FAILED View
LICENSED BONDED PLMBG CONTRCTR EMPLOY LICENSED AND BONDED PLUMBER TO PERFORM PLUMBING WORK. 8056 S RACINE AVE COMPLAINT FAILED View
REMOVE REMOVE ALL ASBESTOS FROM PIPING IN BASEMENT - DANGEROUS AND HAZARDOUS. (11-4-2150 THRU 11-4-2180) 8056 S RACINE AVE COMPLAINT FAILED View
SUPPLY HOT WTR MIN TEMP 120DEG ALL FIXTURES 1ST AND 2ND FLOOR - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
KEEP FIXTUR CLEAN AND SANITARY REMOVE ALL MOLD IN BASEMENT. (13-196-620B - 630B) 8056 S RACINE AVE COMPLAINT FAILED View
STOP ODORS RPR DFT SEWAGE SYS REPLACE BRASS CLEANOUT ON 4" WYE IN BASEMENT AND REPLACE ALL SQUEEZE PLUGS IN BASEMENT WITH BRASS CLEANOUTS. 8056 S RACINE AVE COMPLAINT FAILED View
SOIL/WASTE,VENT PIPE MATRL REPLACE ALL PVC PIPING IN A COMMERCIAL BUILDING. 8056 S RACINE AVE COMPLAINT FAILED View
INSTALL FIXTURES PROPERLY REPLACE ALL FLEX TUBES ON PLUMBING FIXTURES AND WATER HEATER 1ST AND 2ND FLOORS. PROPERLY TRAP AND VENT SINK IN BASEMENT OF LIQUOR STORE. 8056 S RACINE AVE COMPLAINT FAILED View
RESET LOOSE FIXTURE ALL FIXTURES IN LIQUOR STORE, 2ND FLOOR KITCHEN SINK. 8056 S RACINE AVE COMPLAINT FAILED View
PRV BALLCOCK,VB,OR AIR GAP PROVIDE AN AIR GAP FOR FAUCET SERVING 2ND FLOOR NORTH TUB. 8056 S RACINE AVE COMPLAINT FAILED View
PRV FLUE FOR HOT WATER HEATER PROPERLY SUPPORT FLUE SERVING WATER HEATER. 8056 S RACINE AVE COMPLAINT FAILED View
INSTALL COVERS PROVIDE COVERS FOR OPEN JUNCTION BOX AT CEILING OF FRONT ENTRANCE TO LIQUOR STORE, OPEN JUNCTION BOX IN CEILING OF BATHROOM IN LIQUOR STORE, OPEN JUNCTION BOXES IN CEILING AND AT COMPRESSOR ON TOP OF WALK-IN COOLER IN NORTH SECTION OF LIQUOR STORE, AND OPEN JUNCTION BOXES, ELECTRICAL PANELS, AND SERVICE DISCONNECT IN BASEMENT - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
CONTINUITY OF RACEWAY PROVIDE GROUND CONTINUITY FOR FLUORESCENT LIGHT IN FRONT ENTRANCE - SEALTITE NOT PROPERLY CONNECTED TO JUNCTION BOX, ARMORED CABLE AND EXHAUST FAN IN BATHROOM OF LIQUOR STORE, AND 1/2" CONDUIT SEPARATED FROM FITTING ON WEST EXTERIOR NEXT TO GUTTER. ALSO AT COMPRESSOR ON TOP OF WALK-IN COOLER IN NORTH ROOM OF LIQUOR STORE - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
UNAPPROVED CORDS REMOVE EXTENSION CORDS AT ICE MAKER AND COOLER AT REAR OF LIQUOR STORE, ABOVE ELECTRICAL PANEL AT DROPPED CEILING AT REAR OF LIQUOR STORE, AND UNAPPROVED CORD WIRING AT RECEPTACLE BOX BEHIND FRONT COUNTER (NEXT TO PRINTER) - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
CORD TO FIXTURE REMOVE CORD WIRED FLUORESCENT LIGHT BELOW FRONT COUNTER OF LIQUOR STORE. 8056 S RACINE AVE COMPLAINT FAILED View
DEFECTIVE POWER SERVICE REPLACE DEFECTIVE ELECTRICAL SERVICE - OPEN AND RUSTED ELECTRICAL PANELS, AND DISCONNECT, LACK OF GROUND CONTINUITY AND SERVICE DROP NOT ATTACHED TO BUILDING - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
DEFECTIVE FIXTURES REPLACE DEFECTIVE LIGHT FIXTURE IN BATHROOM OF LIQUOR STORE - LOOSE, NO GLOBE AND IMPROPERLY INSTALLED BASEMENT OF LIQUOR STORE - SECURE ALL LOOSE LIGHT FIXTURES, AND REPLACE ALL BROKEN ONES. REPLACE DETECTIVE EXHAUST FAN IN LIQUOR STORE BATHROOM. 8056 S RACINE AVE COMPLAINT FAILED View
EXPOSED WIRING REMOVE EXPOSED WIRING AT FOLLOWING LOCATIONS - EXHAUST FAN IN LIQUOR STORE BATHROOM, OPEN JUNCTION BOXES IN CEILING AND AT COMPRESSOR IN NORTH ROOM OF LIQUOR STORE, OPEN JUNCTION BOX ON EAST EXTERIOR, 1/2" CONDUITS AT REAR BASEMENT STAIRWELL, AND OPEN JUNCTION BOXES AND ELECTRICAL PANELS THROUGHOUT BASEMENT - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
SEE INSPECTOR COMMENTS PROVIDE GFCI PROTECTION AT ALL REQUIRED LOCATIONS - LIQUOR STORE BATHROOM, AND 2ND FLOOR NORTH APARTMENT (KITCHEN). (18-27-210.8) 8056 S RACINE AVE COMPLAINT FAILED View
CORD WIRED EQUIPMENT 2ND FLOOR NORTH APARTMENT - REMOVE EXTENSION CORD WIRING WITH OPEN SPLICE AT WALL HEATER AT BACK DOOR OF APARTMENT - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
REPLACE************** 2ND FLOOR NORTH APARTMENT - REPLACE AIR CONDITIONER WITH DAMAGED CORD (TAPED UP) IN LIVING ROOM (18-27-110.7) DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
OUTDOOR ARMORED CABLE REMOVE ARMORED CABLE AT QUENCH SIGN ON EAST EXTERIOR AND LIGHT FIXTURE ABOVE DOOR ON WEST EXTERIOR EXPOSED TO WEATHER - NOT APPROVED FOR OUTDOOR USE. 8056 S RACINE AVE COMPLAINT FAILED View
CORRODED CONDUIT & EQUIP REPLACE ALL RUSTED CONDUIT ON WEST EXTERIOR OF BUILDING. 8056 S RACINE AVE COMPLAINT FAILED View
SECURE RACEWAY PROPERLY SUPPORT ALL LOOSE CONDUIT THROUGHOUT BASEMENT - CONDUIT THAT CANNOT BE SUPPORTED PROPERLY SHALL BE REPLACED. 8056 S RACINE AVE COMPLAINT FAILED View
SUPPORT OUTLET AND JBOX PROPERLY SUPPORT ALL LOOSE OR HANGING JUNCTION BOXES THROUGHOUT BASEMENT. ALSO SECURE LOOSE A/C DISCONNECT COVERS AT REAR OF BUILDING. 8056 S RACINE AVE COMPLAINT FAILED View
OBTN PERMIT FOR PLUMBING WORK OBTAIN PERMITS FOR PLUMBING BEFORE UNDERTAKING WORK. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR LINTELS SHIFTING LINTELS THROUGHOUT 8056 S RACINE AVE COMPLAINT FAILED View
SEND EX. METAL LETTER SUBMIT ENGINEERS REPORT FOR SIGN ATTACHED TO EAST ELEVATION 8056 S RACINE AVE COMPLAINT FAILED View
FLAKY INTERIOR PAINT 2ND LEVEL APT WINDOWS FLAKING PAINT. 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR OR REPLACE REAR DOWNSOUT DISCONNECTED, 18-29-1101.2.1 8056 S RACINE AVE COMPLAINT FAILED View
PRV FLOOR DRAIN WITH METAL STR NEAR CONDENSATE DRAIN FOR COOLER, IN LIQUOR STORE BATHROOM. 8056 S RACINE AVE COMPLAINT FAILED View
REMOVE STAGNANT WATER BSMT REMOVE STAGNANT WATER AND SEWAGE FROM BASEMENT - DANGEROUS AND HAZARDOUS. 8056 S RACINE AVE COMPLAINT FAILED View
RATS RODENT HOLES IN BASEMENT 8056 S RACINE AVE COMPLAINT FAILED View
REMOVE SEALTITE WITH EXPOSED WIRING AT ELECTRICAL PANEL AT REAR OF LIQUOR STORE (18-27-351.4) 8056 S RACINE AVE COMPLAINT FAILED View
REPAIR GUTTER & DOWNSPOUT CLOGGED GUTTER IN REAR 8056 S RACINE AVE COMPLAINT FAILED View
PERMIT REQUIRED TO CORRECT ALL ELECTRICAL VIOLATIONS (13-12-360) 8056 S RACINE AVE COMPLAINT FAILED View