Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS AND CONDITONS. REAR GATE IS LOCKED, UNABLE TO VERIFY CONDITON OF REAR PORCHES. UNABLE TO VERIFY COMPLAINT OF MICE INFESTATION AND OLD WINDOWS. | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |
POST OWNER/MANAGERS NAME/# | BUILDING / OWNER'S ID SIGN - INCOMPLETE ( MISSING ADDRESS ). | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST ELVATION / EXTERIOR WALL - WASHED OUT MORTAR. | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |
PARAPET | WEST ELEVATION / PARAPET - WASHED OUT MORTAR. | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | SOUTH ELEVATION / 1ST AND 2ND FLOORS / 8 LARGEST WINDOW LINTELS - RUSTED SAGGING AND DETERIORATING. UP TO 1 1/4 INCHES OF MORTAR PACKED BETWEEN LINTELS AND BRICK WORKPLANS AND PERMIT REQUIRED TO REPAIR ALL LINTELS OVER 6 FEET IN LENGTH. | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |
REPAIR PORCH SYSTEM | REAR 2 STORY FRAMED PORCHES/ BOTH WITH SIMILAR DEFECTS COLUMNS ERECTED ON TOP OF CONCRETE SLAB,WITH NO BASES,FOUNDATION STATUS UNKNOWN,SOME COLUMNS RESTING ON CONCRETE BLOCKS.COLUMNS RESTING ON CONCRETE BLOCKS,COLUMNS ARE OUT OF PLUMB BOWING AND TWISTING,COLMNS - OVER-NOTCHED WITH FIRECUTS,RIM JOIST,BEAM AND SPLICE CONNECTIONS OCCURING AT SOME LOCATION OR IN CLOSE PROXIMITY AND ONLY INCHES APART,COLMNS LAP JOINTS ONLY OVERLAPS 12 INCHES WITH A 2 BOLT PATTERN,LOOKOUT 6X6 BEAM SPANS OUT 8 FOOT,2X8 JOISTS SPACED 24" APART,ALL JOISTS FASTERNED TO HEADER JOISTS AND RIM JOISTS,WITH TOE NAILS ONLY,UPPER END OF STRINGER TOENAILED INTO JOIST ONLY.ENTIRE FLIGHT OF STAIRS FROM 1ST TO 2ND FLOOR WEAK,UNSTABLE AND SWAYS,TREADS WORN OUT,CRACKED,BROKEN,WEAK AND PULLING AWAY.GUARDRAILS UNDERSIZED AND OVER SPANNED,MISSING SUPPORT POSTS.HANDRAILS UNDERSIZED,ALL TOP AND BOTTOMS OF RAILS TOENAILED INTO POSTS,DECKING WEATHERED AND WORN WITH CRACKS,COLUMN TO ROOF CONNECTEN INTO FIRE CUT SUPPORTED BY SCAB BLOCKING.ROOF OVER PORCH- SHEATHY SOAKED AND NOTTED.SUBMIT PLANS AND OBTAIN PERMIT TO REBUILD BOTH PORCHES. | 7557 S EBERHART AVE | COMPLAINT | FAILED | View |