The Open Source Data Files that are here are from Cook County.
This Page is a combination of all Files.
The Parcel Universe and most other Cook County files are categorized by PIN and Tax Year.
This page is PIN ONLY. You can expand this page (at the bottom) to see lists of all files related to this Pin.
The 2023 Data is from the Parcel Universe File with Tax_Year = 2023.
Violation | Inspector Comments | Address | Category | Status | View |
---|---|---|---|---|---|
ARRANGE PREMISE INSPECTION | NO RESPONSE; NO ENTRY. UNABLE TO INSPECT INTERIOR, STAIRWELL, APARTMENTS, BASEMENT, REAR PREMISES, AND REAR PORCH. UNVERIFIED DETECTORS AND OCCUPANCY. | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
REPAIR EXTERIOR WALL | WEST - EXTERIOR WALL - CRACKED, BUCKLING MORTAR SKIM COAT ABOVE 3RD FLOOR WINDOW | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
REPAIR LINTELS | WEST LINTELS - RUSTED.( REPLACE IF RUSTED WITH HOLES OR SAGGING). | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
REMV OBSTR FROM DRAINAGE SYSTM | REAR BASEMENT AREWAY, FLOOR DRAIN - CLOGGED. | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
WORK NOT ALLOWED | REMOVE ALL PARTITIONS AND FIXTURES PLUMBING AND ELECTRIC INSTALLED IN THE BASEMENT (NORTH).ORIGINAL BASEMENT STORAGE SPACE HAS BEEN ALTERED INTO A DWELLING UNIT ( NO PLANS AND PERMIT ON RECORD). | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
PLANS & PERMITS REQ - CONTRCTR | SUBMIT PLANS AND OBTAIN PERMIT FOR ALL RELATED WORK TO AUTHORIZE ALTERATIONS TO THE BASEMENT OR RESTORE BUILDING TO THE ORIGINAL SPACE. | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
WINDOW AREA ABOVE GROUND | BASEMENT ILLIGAL DWELLING UNIT BEDROOM WINDOWS ARE 28"X34". | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
REPLACE D&H PORCH | REAR 3 STORY WOOD PORCH, COLUMNS ERECTED ON TOP OF CONCRETE BASES AND ON TOP OF CONCRETE SLAB; FOUNDATION STATUS UNKNOWN.COLUMNS ARE STACKED ON TOP OF BEAMS AND FASTENED WITH NAILS OR LIGH GAGE METAL TIE STRAPS; SOUTH 3RD FLOOR COLUMN SEGMENT IS BUCKLING OUT (CREATING A DANGEROUS AND HAZARDOUS CONDITION)UNDERSIZED 6"X6" BEAMS SPAN 6'-7".UNDERSIZED 2"X8" DECK JOISTS SPAN 12'-0".STRINGERS ARE FASTENED WITH NAILS ONLY; STAIR TREADS ARE 9-1/4" WIDE.PLYWOOD USED AS DECKING MATERIAL.GUARDRAILS ARE ONLY 38" HIGH; END POST RO WALL FASTENED WITH NAILS ONLY.HANDRAILS ARE OF LADDER TYPE DESIGN, WITH HORIZONTAL RAILS UP TO 7-1/2" APART.PLANS AND PERMIT ARE REQUIRED TO REPLACE D&H PORCH | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
REPAIR EXTERIOR DOOR | FRONT MAIN ENTRY DOOR - LOOSE LITE GLASS PANE. | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
FILE BLDG REGISTRATION | BUILDING - HAS NERVER BEEN REGISTERED. | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |
DEFECTIVE FIXTURES | DEFECTIVE LIGHT FIXTURES IN KITCHEN AND PANTRY APARTMENT 1N. | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
SMOKE DETECTOR NOT WITHIN 15 FEET OF BEDROOM DOORS. 18-27-570.10(G) | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View | |
REPAIR EXTERIOR DOOR | WEST - FRONT ENTRY DOOR - CRACKED, BROKEN GRILLE AT DOORLITE | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
FILE BLDG REGISTRATION | BUILDING - HAS NERVER BEEN REGISTERED. | 4417 S PRAIRIE AVE | COMPLAINT | FAILED | View |
WINDOW AREA ABOVE GROUND | BASEMENT ILLIGAL DWELLING UNIT BEDROOM WINDOWS ARE 28"X34". | 4417 S PRAIRIE AVE | COMPLAINT | PASSED | View |