PIN: 20091050380000
Property Address: 4822 S UNION AVE
City - Zip: CHICAGO - 60609
2023 Property Class: 211
2023 Township: 72 - Lake
2023 Neighborhood: 72051
2023 Tax District: 72103
Cook Viewer GIS: External GIS Website
Chicago Building Violations Data: 9 Violations
Violation Inspector Comments Address Category Status View
POST OWNER/MANAGERS NAME/# BUILDING NO OWNERS ID SIGN POSTED 4822 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR STAIR EAST ELEVATION-CONCRETE STAIRS-CRACKS BETWEEN RISER AND TREADS-LEFT STONE RAILING-LOOSE AND PULLING. NORTH AND SOUTH ELEVATION. WASHED OUT MORTAR, GRADE TO BASEMENT MISSING RAIL 4822 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR WALL EAST ELEVATION 2ND FLOOR-SOUTH 2ND FLOOR AND AT GRADE-WEST AT GRADE-WASHED OUT MORTAR 4822 S UNION AVE COMPLAINT FAILED View
REPAIR EXTERIOR PLATFORM SIDE YARD-SOUTH ELEVATION-SWINGING POOL DECK-ROTTED JOIST AND DECKING-4X4 POST FACE NAILED: LOOSE AND SEPARATING. RAILINGS ARE LADDER TYPE WITH SECTIONS MISSING ENTIRE STRUCTURE IS LOOSE AND SHAKY. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIRS OR REPLACEMENT OF SIDE DECK 4822 S UNION AVE COMPLAINT FAILED View
REPLACE D&H PORCH (SR 801471413)REAR TWO STORY PORCH-6X6 COLUMNS RESTING ON CONCRETE PIERS, FOUNDATION STATUS UNKNOWN-LEDGER BOARDS ARE MISSING BOLTS-JOIST ARE 2X10" WITH 13' SPAN. RIM JOIST FACE NAILED-BEAMS ARE 2X10"-SPAN-13' MISSING BOLTS AND TIE STRAPS-BEAM AND COLUMN CONNECTION FACED NAILED COLUMNS ARE 6X6 OVER NOTCHED-STAIR IMPROPER. DESIGN-STINGER ARE RABBITED OUT TO ACCEPT. TREADS-PULLING APART WITH TREADS FALLING OUT OF NOTCH.WITH ROTTED AND CRACKING STRINGERS AND TREADS-DECKING-CRACKING AND CUPPING WITH SOME PIECES LOOSE. RAILING, CRACKING AND WORN. MISSING BOLTS LOOSE AND PULLING. SUBMIT PLANS AND OBTAIN PERMIT FOR REPAIR OR REPLACEMENT OF REAR PORCH 4822 S UNION AVE COMPLAINT FAILED View
OPEN 4822 S UNION AVE PERMIT PASSED View
POST OWNER/MANAGERS NAME/# BUILDING - NO OWNER'S ID SIGN POSTED. 4822 S UNION AVE COMPLAINT FAILED View
ARRANGE PREMISE INSPECTION INTERIOR OF BUILDING - NO RESPONSE, UNVERIFIED DETECTORS, CONDITIONS AND OCCUPANCY. 4822 S UNION AVE COMPLAINT FAILED View
CUT OR REMOVE HIGH WEEDS REAR AND SIDE YARD-HIGH WEEDS 4822 S UNION AVE COMPLAINT FAILED View